BASIC SET ON(0xFF) and OFF(0x00) command while vacation 
mode is enable and disable. 
   

 

z

 

COMMAND_CLASS_CONFIGURATION 

Device reserves 255 bytes memory store space use for upper 
application. Upper application could access the memory by 
configuration command class, default setting always set to zero 
(0x00) , parameter size always set to one (0x01), parameter possible 
value could be from 0x00 to 0xFF which is decided by upper 
application. 

 

z

 

COMMAND_CLASS_DOOR_LOCK 

Device has two(2) difference relock mode, auto-relock mode (Timed 
Operation) and constant-unlock mode (Constant Operation). It can 
setting by manual or Door Lock Configuration Command. Auto-
relock timeout fix in eight (8) seconds. 
Device treats constant Unsecure setting of Door Lock Operation as 
Unsecure with timeout while device auto-relock mode is enable. 

 

z

 

COMMAND_CLASS_NODE_NAMING 

Device report Node Name Report in ASCII with brand name and 
production version inform after retrieve factory default. 

 

z

 

COMMAND_CLASS_SCHEDULE_ENTRY_LOCK 

Device doesn

t support Daylight Saving function. It will ignore DST 

offset of Schedule Entry Lock Time Offset Set Command. 
Device supports Duration Hour of Schedule Entry Lock Daily 
Repeating Set command from zero (0) to 168 (=7x24) maximum.  
 

z

 

COMMAND_CLASS_USER_CODE 

 
Device user code fix to six(6) digits. It will ignore User Code Set 
Command if user code length no equal to six digits. 
 
Z-Wave Certification No

ZC08-13100011 

Summary of Contents for Z-WAVE DIGITAL LOCK

Page 1: ...LS 8015 ZW MM BG Manual Operation Guide...

Page 2: ...Restore Factory Default a Disconnect 1pcs battery b Press and hold the reset button c While holding the reset button reconnect the battery d Until the lock beeps release the reset button e Press digi...

Page 3: ...y to change the default Programming Code User code 6 digits User code is the normal code for day to day operations Z Wave Every unlocking need be through Z wave Controller Index No 2 digits For each u...

Page 4: ...ming code 4 new programming code new programming code 2 How to add one user code Function Code 1 programming code 1 user code user code 3 How to delete one user code with index No Function Code 2 prog...

Page 5: ...lock it by press star key on the keypad manually 9 How to enroll unenroll lock to Z wave network Enroll z Put the Z wave controller into enroll mode z Input programming code 0 lock is into enroll mode...

Page 6: ...ific Device Class SPECIFIC_TYPE_SECURE_KEYPAD_DOOR_LOCK FLIRS setting APPLICATION_FREQ_LISTENING_MODE_1000ms Device is a security enabled Z wave production implements Z Wave Application Security Layer...

Page 7: ...ACTURER_SPECIFIC VERSION SECURITY APPLICATION_STATUS ALARM ASSOCIATION BASIC BATTERY CONFIGURATION DOOR_LOCK DOOR_LOCK_LOGGING NODE_NAMING SCHEDULE_ENTRY_LOCK TIME_PARAMETERS USER_CODE Z Wave Command...

Page 8: ...or Door Lock Configuration Command Auto relock timeout fix in eight 8 seconds Device treats constant Unsecure setting of Door Lock Operation as Unsecure with timeout while device auto relock mode is...

Reviews: