26
English
Our Kärcher branch will be pleased to help you further in the case of
questions or faults. See address on the reverse.
Subject to technical modifications!
The irrigation process
was terminated manu-
ally (the symbol for the
deactivated irrigation
will appear on the dis-
play).
Activate irrigation
programme.
Leakage at the wa-
ter connection.
Filter gasket defective.
Replace the filter
gasket.
The water connection
at the water tap has be-
come loose.
Reconnect the
water connection.
Specifications
Operating pressure
0,1 - 1 (1 - 10) MPa (bar)
Max. feed temperature
30
°C
Ambient temperature
+1 -> +40
°C
Battery type
9V (6LR61 / Alkaline)
Fault
Cause
Remedy