English
21
Troubleshooting
Fault
Cause
Remedy
The irrigation will
not start at day-
break but always at
the time the pro-
gramme was acti-
vated.
Necessary light condi-
tions are not achieved.
The programme will al-
ways start 24 hours af-
ter the first
programming.
Align the irriga-
tion device with
the light source or
install in a differ-
ent location.
The irrigation will
start at different
times.
The irrigation start de-
pends on the time of
daybreak.
The operation of
the irrigation de-
vice is not affect-
ed.
The irrigation does
not take place in
spite of the pro-
gramming.
Water tap is closed.
Open tap.
Battery depleted.
Insert a new 9V
battery (type
6LR61 / Alkaline).
Battery contacts oxi-
dized.
Clean the con-
tacts.
Filter gaskets blocked.
Clean the filter
gasket.