background image

     - 

8

Operations log WPC

(A) Startup date with transfer log

Plant type: 1.024-

Plant number:

Startup date:

Installation site:

Type of raw water source:

Customer:

Operating hours display [h]

Raw water hardness [°dH]

Flow rate of raw water [

μ

S/cm]

pH value fo raw water [pH]

Raw water temperature [°C]

Media filter of inlet pressure during plant running 
[MPa]

Media filter of inlet pressure during return rinsing [MPa]

Active carbon filter of inlet pressure during plant run-
ning [MPa]

Active carbon filter of inlet pressure during return rins-
ing [MPa]

Inlet pressure of fine filter [MPa]

Outlet pressure of fine filter [MPa]

Concentrate pressure [MPa]

Membrane input pressure [MPa]

Drinking water quantity [l/h]

Concentrate quantity [l/h]

Yield [%]

Drinking water flow rate [

μ

S/cm]

Dosing pump flocking stroke/ frequency [%]

Dosing pump pre-chlorination stroke/ frequency [%]

Dosing pump anti-scalant stroke/ frequency [%]

Dosing pump post-chlorination stroke/ frequency [%]

Remarks

Confirmation: The plant was started up and handed over in a fully functioning condition.  It has been explicitly brought to the notice 
of the customer that the watre produced by the plant must be checked according to the local standards by an approved testing agen-
cy before releasing it as drinking water.  Further, it has also been brought to the notice of the customer that the operations log is to 
be maintained; the customer has also been informed about the risks involved in handling chemicals and the hazards on account of 
interchanging the chemicals.

Place, Date, Signature (Customer)

Place, Date, Signature (Kärcher Service)

20

EN

Summary of Contents for WPC 5000 SW-AM

Page 1: ...R egister and w in w w w kaercher com WPC 5000 SW AM 59620150 05 12 Deutsch 3 English 13 Espa ol 23...

Page 2: ...2...

Page 3: ...Deutsch 1 3 DE...

Page 4: ...erverletzungen oder zum Tod f hrt Warnung F r eine m glicherweise gef hrliche Situa tion die zu schweren K rperverletzungen oder zum Tod f hren k nnte Vorsicht F r eine m glicherweise gef hrliche Situ...

Page 5: ...urch den K rcher Kundendienst durchgef hrt werden Hauptschalter auf 0 drehen die Anla ge stoppt die Trinkwasserproduktion Hinweis Anlage nicht ber Nacht abschalten Nachts wird die automatische Reinigu...

Page 6: ...PC 5000 SW AM 1 Entl ftung 2 Filterdeckel 3 Filtergeh use 4 Probenahmehahn Rohwasser 1 Knebelschraube 2 Filterkerze Feinfilter an Probenahmehahn Roh wasser drucklos machen Filterdeckel abschrauben Was...

Page 7: ...tzen Kanister aus der Dosierstation entneh men Gefahr Verletzungsgefahr durch chemische Reak tion Die Dosierstationen d rfen nicht ver wechselt und dadurch mit der falschen Chemikalie bef llt werden W...

Page 8: ...twertsonde defekt Kundendienst verst ndigen Wassermangel Feinfilter verstopft Austauschen mit St rungstaste quittieren Rohwasserzufuhr unterbrochen Rohwasserzufuhr wiederherstellen gegebenenfalls Kund...

Page 9: ...n kann Weitere Informationen ber Ersatzteile erhalten Sie unter www kaercher com im Bereich Service Technische Daten WPC 5000 SW AM Umgebungstemperatur C 1 50 Lagertemperatur min C bis 10 Luftfeuchtig...

Page 10: ...ge l h Ausbeute Trinkwasserleitf higkeit S cm Dosierpumpe Flockung Hub Frequenz Dosierpumpe Vorchlorung Hub Frequenz Dosierpumpe Antiscalant Hub Frequenz Dosierpumpe Nachchlorung Hub Frequenz Bemerkun...

Page 11: ...nfilter MPa 1Pr01 Druck nach Feinfilter MPa 1Pr02 Pumpendruck MPa 1Pr04 Membraneingangsdruck MPa 1Pr05 Konzentratdruck MPa 1Pr 06 Konzentratmenge l h 1Fl01 Anzahl R cksp lungen Mediafilter Anzahl R ck...

Page 12: ...10 R ckseite Bleibt leer damit das Blatt herausgetrennt werden kann 12 DE...

Page 13: ...English 1 13 EN...

Page 14: ...diately Never operate the unit with damaged cable Danger Immediate danger that can cause severe injury or even death Warning Possible hazardous situation that could lead to severe injury or even death...

Page 15: ...t some preservative tasks Turn main switch to 0 the plant will stop production of drinking water Note Do not switch off the plant overnight The prefilters are automatically cleaned during the night Th...

Page 16: ...0 SW AM 1 Venting 2 Filter cover 3 Filter casing 4 Sample extraction tap raw water 1 Thumb screw 2 Filter candle Take the pressure of the fine filter on sample extraction tap raw water Maintenance sch...

Page 17: ...and safety goggles Remove the can from the dosing sta tion Danger Risk of injury on account of chemical reac tion The dosing stations should not get in terchanged and be filled up with the wrong chemi...

Page 18: ...e Inform Customer Service Low water pres sure Fine filter blocked Replace acknowledge with fault key Raw water inflow interrupted Reestablish the raw water inflow notify customer ser vice if necessary...

Page 19: ...For additional information about spare parts please go to the Service section at www kaercher com Technical specifications WPC 5000 SW AM Ambient temperature C 1 50 Storage temperature min C up to 10...

Page 20: ...h Concentrate quantity l h Yield Drinking water flow rate S cm Dosing pump flocking stroke frequency Dosing pump pre chlorination stroke frequency Dosing pump anti scalant stroke frequency Dosing pump...

Page 21: ...Pressure after fine filter MPa 1Pr02 Pump pressure MPa 1Pr04 Membrane input pressure MPa 1Pr05 Concentrate pressure MPa 1Pr 06 Concentrate quantity l h 1Fl01 Number of backflows Media filter Number o...

Page 22: ...10 Rear side Is kept blank so that the sheet can be separated 22 EN...

Page 23: ...Espa ol 1 23 ES...

Page 24: ...un cable de alimentaci n da ado Peligro Para un peligro inminente que acarrea le siones de gravedad o la muerte Advertencia Para una situaci n que puede ser peligro sa que puede acarrear lesiones de g...

Page 25: ...n durante m s de 14 d as se debe llevar a cabo una conserva ci n por parte del servicio de atenci n al cliente de K rcher Girar el interruptor principal a 0 la ins talaci n para la producci n de agua...

Page 26: ...1 purga de aire 2 Tapa del filtro 3 Carcasa del filtro 4 Grifo de toma de muestras de agua no tratada Plan de mantenimiento Cu ndo Controles tarea Valor nominal En caso de divergen cia A diario Nivel...

Page 27: ...gafas de seguridad Sacar el bid n de la estaci n de dosifi caci n Peligro Peligro de lesiones por una reacci n qu mi ca Las estaciones de dosificaci n no se pueden intercambiar y llenar con las sus ta...

Page 28: ...cla de aver a Alimentaci n de agua no tratada interrumpida Restablecer alimentaci n de agua no tratada si es necesario informar al servicio t cnico Presostato defectuoso Informar al servicio t cnico M...

Page 29: ...ww kaer cher com encontrar m s informaci n sobre piezas de repuesto Datos t cnicos WPC 5000 SW AM Temperatura ambiente C 1 50 Temperatura de almacenamiento m n C hasta 10 Humedad del aire m x rel 100...

Page 30: ...del concentrado MPa Presi n de entrada de la membrana MPa Caudal de agua potable l h Cantidad de concentrado l h Resultado Conductividad agua potable S cm Bomba dosificadora floculaci n carrera frecu...

Page 31: ...MPa 1Pr01 Presi n tras el filtro fino MPa 1Pr02 Presi n de la bomba MPa 1Pr04 Presi n de entrada de la membrana MPa 1Pr05 Presi n del concentrado MPa 1Pr 06 Cantidad de concentrado l h 1Fl01 N mero de...

Page 32: ...10 Parte posterior En blanco para separar la hoja 32 ES...

Reviews: