21
201
Plant not in operation (operational time
switched off)
Night switch off of the unit is active, key
switch of the feed distributor is positioned
at "0"
Check key switch of the feed distributor
(position it to 1 or 2)
203
Portal not in normal setting
Unit not in normal setting
Drive unit to normal setting
204
Side-brushes not facing outwards
205
Side-brush 1 not facing outwards
206
Side-brush 2 not facing outwards
207
Release signal missing
Release signal by external control to sig-
nal distributor missing.
Test the release signal; if there is no ex-
ternal control: Install the wire jumper as
per circuit diagram.
208
Roof brush not facing upward
Unit not in normal setting
Drive unit to normal setting
209
High pressure roof bar not up
220
Door 1 is not closed
Drive-in door did not reach end position
Check door
221
Door 1 is not opened
222
Door 2 is not closed
Drive-out door did not reach end position
223
Door 2 is not opened
226
Fault door 1, light barrier 1
Light barrier is contaminated, blocked or
defective
Clean light barrier.
Turn off the equipment, wait, turn on the
equipment.
227
Fault door 1, light barrier 2
228
Fault door 2, light barrier 2
229
Fault door 2, light barrier 1
234
Light barrier position 1 blocked
235
Light barrier position 2 blocked
236
Fault front drier light barrier / roof bar front
down
237
Fault middle drier light barrier / roof bar up
238
Fault rear drier light barrier / roof bar rear
down
239
Fault in high pressure sequence (light bar-
rier of high pressure roof bar activated for
more than 10 seconds)
240
Safety switch of high pressure roof bar
has been triggered during the wash cycle.
Obstacle, safety switch stuck
Clean light barrier.
Check the safety switch with the end
switches for ease of movement and dam-
ages. Switch the system off and back on,
repeat wash cycle
241
Fault of the high pressure roof bar during
drive into base position (light barriers,
safety switch)
Light barrier is contaminated, blocked or
defective
Obstacle, safety switch stuck
242
Fault of the high pressure roof bar light
barrier at the beginning of the wash cycle
Light barrier is contaminated, blocked or
defective
Clean light barrier.
Turn off the equipment, wait, turn on the
equipment.
245
No vehicle found after the wash pro-
gramme was started
No vehicle in the wash system
Drive vehicle in
246
Radio operator station out of order
Radio operator station switched off during
wash cycle or batteries of the operator
station depleted.
Replace the batteries, switch on the radio
operator station and press the "Start/
Stop" key.
or
Press the "Start/Stop" key on a wired op-
erator station.
247
Error while writing/reading via the USB in-
terface
USB stick defective or memory full.
Delete the USB stick or used a different
USB stick.
Turn off the equipment, wait, turn on the
equipment.
If the event recurs, call Customer Service.
248
Error while writing/reading the memory of
the control.
Memory of control full or defective.
Turn off the equipment, wait, turn on the
equipment.
If the event recurs, call Customer Service.
250
Unit has not been initialised
Measurement drive has not yet been done Washing is not possible; call Customer
Service
251
Emergency operations of processed wa-
ter are active
Processed water unit has a fault
Repair service water system
255
Fault, wash data invalid
The updated wash data is no longer valid
or have the wrong version
Use new wash data.
Dis-
play
Fault
Possible cause
Remedy
23