14
Danger
Risk of electric shock!
Work on electrical plant only to be carried
out by qualified electricians.
Switch the plant to voltage-free with all
work, in this case switch the plant at the
main switch to “0”and secure against it
switching on again.
Who may remedy faults?
Operator
Work designated with the sign “Operator”
may only be carried out by persons who
have been instructed in the safe operation
and maintenance on the wash plant
Electricians
Persons with a professional training in the
electro-technical area.
Customer Service
Work designated with the sign “Customer
Service” may only be done by the fitters of
Kärcher Customer Service or fitters who
have been authorised by Kärcher.
Danger
Risk of electric shock.
Switch on the plant voltage-free, in addition
switch on the main switch to “0” and secure
it against being switched on again.
Risk of injury from compressed air unex-
pectedly emerging. . Compressed air con-
tainers also remain under pressure after
the plant has been switched off. It is abso-
lutely necessary to get rid of pressure be-
fore starting work on the system.
Risk of injury from high-pressure water jet
unexpectedly emerging. It is absolutely
necessary to remove all pressure in the
high-pressure system before starting work
on the plant.
Risk of eye injuries from parts flying off or
dirt. Keep clear off rotating brushes. Gog-
gles must be worn during maintenance
work.
If the "drive forward" and "drive backwards"
signal of the traffic light blinks, then one of
the faults mentioned below has occurred.
Troubleshooting
Positioning traffic light fault indicator (option)
Number of
blinks
Fault
Possible cause
Remedy
twice
Water cabinet door open
Not all 3 locks are locked
Lock all 3 locks.
thrice
Short/ narrow hall switch pressed (Op-
tion)
The switch has been pressed by a
person
One or more switches have been
pressed; reset switch manually.
Press the "Start/Stop" key to contin-
ue the wash.
four times
Safety equipment high pressure roof bar
actuated
Safety switch of high pressure roof
bar has been triggered.
Check the safety switch ob high
pressure roof bar.
5 times
Frost protection is active
Frost proteciton is active
Washing cannot be done until the
anti-frost temperature is exceeded
again