– 10
Often, failures have simple causes and you
can do the troubleshooting yourself using
the following overview. If you are in doubt
or if the failure is not listed here please con-
tact the authorized customer service.
Danger
Repair works may only be performed by the
authorized customer service.
Always disconnect the mains plug and al-
low the steam cleaner to cool down before
performing any maintenance work.
Decalcify appliance.
Refill water
Steam switch is secured with the lock /
child-proof lock.
Push the steam switch lock to the back.
Remove the nozzle insert from steam
nozzle. To do this, rotate the nozzle in-
sert counter-clockwise with a coin and
pull the nozzle insert out.
Clean the nozzle insert.
Briefly switch on the appliance.
Reinstall the nozzle insert into the
steam nozzle and tighten the nozzle in-
sert in a clockwise direction.
The safety thermostat turns off the appli-
ance if the boiler thermostat and the pres-
sure controller fails and the appliance
overheats in case of a malfunction. Please
contact your local KÄRCHER customer
service to arrange for the reset of the safety
thermostat.
Subject to technical modifications!
Order number
Troubleshooting
Decreased steam amount
Appliance is decalcified.
Steam decreases during the work /
no steam
No water in the water reservoir.
Steam lever cannot be pressed
anymore
Steam nozzle is plugged
Safety thermostat
Technical specifications
Electrical connection
Voltage
220-240
1~50
V
Hz
Protection class
IP X4
Protective class
I
Performance data
Heating output
1600 W
Dimensions
Water reservoir
0,25 l
Length
190 mm
Width
100 mm
Height
280 mm
Weight (without accessories) 1,2
kg
Special accessories
Round brush kit
2.863-058
4 round brushes for the detail nozzle
Round brush kit with brass
bristles
2.863-061
Removal of especially stubborn dirt ideal
for insensitive surfaces.
Round brush with scraper
2.863-140
Round brush with two rows of heat-resist-
ant bristles and a scraper. Not suitable for
sensitive surfaces.
Decalcifying sticks (9 pieces)
6.295-206
16