background image

English

17

6. Drain the water completely out of the steam boiler.

Illustration V

ATTENTION
Appliance damage due to descaler

An unsuitable descaler or incorrect dosing of the descal-
er may damage the appliance.
Only use KÄRCHER descaler.
Use 1 dosing unit of the descaler for 0.5 l water.

7. Apply descaler solution to the descaler according to

the details.

8. Fill the descaler solution into the steam boiler. Do 

not seal the steam boiler.

9. Allow the descaler solution to take effect for 

approx. 8 hours.

10. Drain descaler solution completely out of the steam 

boiler.

11. Repeat the descaling process if necessary.

12. Rinse the steam boiler 2-3 times with cold water in 

order to drain all the descaler solution residue.

13. Drain the water completely out of the steam boiler.

14. Dry the mounting for the grid connection cable.

15. Close the maintenance lock with an extension tube.

Care of accessories

(Accessories - depending on scope of delivery)

Note

The micro fibre cloths are not suitable for dryer.

Note

When washing the cloths, observe the instructions on 
the washing tag. Do not use any liquid softeners as this 
will affect the ability of the cloths to pick up dirt.

1. Wash the floor cleaning cloths and covers at a max. 

temperature of 60 °C in the washing machine.

Troubleshooting guide

Malfunctions often have simple causes that you can 

remedy yourself using the following overview. When in 

doubt, or in the case of malfunctions not mentioned 

here, please contact your authorised Customer Service.

WARNING

Risk of electric shock and burns

Trying to eliminate faults while the appliance is connect-
ed to the mains or has not yet cooled down is always 
dangerous. 
Remove the mains plug.
Allow the appliance to cool down.

The water shortage indicator light flashes red and a 
signal tone sounds

No water in the tank.

Fill the water reservoir up to the “MAX” marking.

The water shortage indicator light is lit in red

No water in the steam boiler. The pump’s overheat pro-

tection has triggered.

1. Switch the device off; see Chapter 

 Switching off the 

device

.

2. Fill the water reservoir.

3. Switch on the device; see Chapter 

 Switching on the 

device

.

The water tank is not inserted correctly or is calcified.

1. Remove the water reservoir.

2. Rinse the water reservoir.

3. Insert the water reservoir and press downwards until 

it locks into place.

The steam lever cannot be pressed

The steam lever is locked with the child lock.

Set the child lock (selector switch for steam volume) 

to the front.

The steam lever is released.

Long heating-up time

The steam boiler is scaled.

Descale the steam boiler.

High water output

The steam boiler is scaled.

Descale the steam boiler.

The steam pressure iron “spits” water

Rinse or descale the steam boiler of the steam 

cleaner; see Chapter

 Descaling the steam boiler

After ironing breaks, water droplets come out of the 
steam pressure iron

During longer ironing breaks, steam can condense in 

the steam line.

After pauses in the ironing process, direct the blast 

of steam onto a cloth until the steam flows evenly.

Technical data

Subject to technical modifications.

Electrical connection

Voltage

V

220-240

Phase

~

1

Frequency

Hz

50-60

Degree of protection

IPX4

Protection class

I

Device performance data

Heating capacity

W

2000

Heating capacity of iron

W

700

Maximum operating pressure

MPa

0.35

Heating-up time

Minutes 4

Continuous steaming

g/min

50

Maximum steam blast

g/min

110

Filling quantity

Water reservoir

l

0.8

Steam boiler

l

0.5

Dimensions and weights

Weight without accessories

kg

4

Length

mm

350

Width

mm

280

Height

mm

270

Summary of Contents for SC 4 EasyFix Iron

Page 1: ...ran ais 18 Italiano 24 Nederlands 31 Espa ol 37 Portugu s 44 Dansk 51 Norsk 57 Svenska 63 Suomi 69 75 T rk e 82 88 Magyar 96 e tina 102 Sloven ina 108 Polski 114 Rom ne te 121 Sloven ina 128 Hrvatski...

Page 2: ...A 2...

Page 3: ...B MAX 0 8 l 2 1 C MAX 0 8 l D 1 2 E 1 2 F G H 1 2 I J 1 2 K L M 3...

Page 4: ...N O P 1 2 R S T 1 2 U V 4...

Page 5: ...ents General notes Read these original operating instruc tions and the enclosed safety instruc tions before using the device for the first time Proceed accordingly Keep both books for future reference...

Page 6: ...ct the responsible K RCHER Customer Service Boiler thermostat The boiler thermostat switches off the heating in the event of a fault for example if there is no water in the steam boil er and the tempe...

Page 7: ...um of 50 distilled water mixed with tap water Do not use condensation from the clothes dryer for fill ing Do not use collected rain water for filling Do not use cleaning agents or other additives e g...

Page 8: ...nd brush and nozzles to the medium sized mount for accessories 5 Hang the floor nozzle in the park bracket Illustration S 6 Wind the steam hose around the extension tube and connect the steam gun to t...

Page 9: ...n tube Illustration M 3 Fasten the floor cleaning cloth to the floor nozzle a Place the floor cleaning cloth with the hook and loop fastener strips pointing upwards on the floor b Place the floor nozz...

Page 10: ...abrics and imprints on the back with steam without direct contact with the iron Steaming the fabrics at a distance of 2 to 3 cm will gently straighten the fibres Note The iron is fitted with an automa...

Page 11: ...ains plug Allow the appliance to cool down The water shortage indicator light flashes red and a signal tone sounds No water in the tank Fill the water reservoir up to the MAX marking The water shortag...

Reviews: