background image

English

13

Note 

The granulate in the cartridge may change colour after 
it comes into contact with water. This depends on the 
mineral content in the water. This discolouration is 
harmless and does not have a negative effect on the de-
vice, cleaning work or the functionality of the decalcifi-
cation cartridge.

Note 

Do not pause for longer than 15 seconds when setting 
as the device will otherwise be set automatically to the 
last selected water hardness or the highest water hard-
ness set during initial start-up. 

1. Connect the mains plug.
2. Make sure that the device is switched off.
3. Press the RESET key and hold it while the device is 

switched on.

Illustration G

After approximately 2 seconds, the indicator light 
flashes and signals the current water hardness set-
ting with the number of pulses.

4. Press the RESET key repeatedly to change the wa-

ter hardness level.

Note

When the RESET key is pressed, the flash pulse for 
the water hardness level is not indicated.

5. Release the RESET key.

The flash pulse for the set water hardness is indicat-
ed.

6. Repeat the process as necessary until the desired 

water hardness level has been achieved.

7. Press and hold the RESET key for 3 seconds to 

save the setting for the water hardness level.
The indicator light for the water hardness lights up.

Care of accessories

(Accessories - depending on scope of delivery)

Note 

The floor cleaning cloth and the cover for the manual 
nozzle have been washed beforehand and can be used 
immediately for working with the appliance. The micro 
fibre cloths are not suitable for dryer.

Note 

When washing the cloths, observe the instructions on 
the washing tag. Do not use any liquid softeners as this 
will affect the ability of the cloths to pick up dirt.

1. Wash the floor cleaning cloths and covers at a max. 

temperature of 60 °C in the washing machine.

Troubleshooting guide

Malfunctions often have simple causes that you can 
remedy yourself using the following overview. When in 
doubt, or in the case of malfunctions not mentioned 
here, please contact your authorised Customer Service.

WARNING

Risk of electric shock and burns

Trying to eliminate faults while the appliance is connect-
ed to the mains or has not yet cooled down is always 
dangerous. 
Remove the mains plug.
Allow the appliance to cool down.

The water shortage indicator light flashes red

The dry-run protection for the pump is deactivated.
1. Switch the device off and back on again.
2. Make sure that the decalcification cartridge has

been inserted correctly and there is sufficient water 
in the reservoir.

The water shortage indicator light lights up con-
stantly in red

No water in the water reservoir.
1. Top up the water reservoir, see chapter Topping up 

the water.

The steam lever cannot be pressed

The steam lever is locked with the child lock.

Set the child lock (selector switch for steam volume) 
to the front.
The steam lever is released.

No / little steam although there is water in the reser-
voir

The decalcification cartridge has not been inserted or 
has been inserted incorrectly.

 Insert the decalcification cartridge or insert it cor-
rectly.

The decalcification cartridge has been removed while 
topping up the water.

Leave the decalcification cartridge in the device 
when topping up.

New decalcification cartridge has been inserted.

Press and hold the steam lever constantly.
The full steam output is reached after approximately 
30 seconds.

Red indicator light "replace descaling cartridge" 
lights up / flashes

Run time of the decalcification cartridge ends soon.

Insert the new decalcification cartridge and reset the
maintenance indicator, see chapter Replacing the 
decalcification cartridge.

The RESET key was not pressed after replacement of 
the decalcification cartridge.

Press and hold the RESET key for 4 seconds after
inserting the decalcification cartridge, see chapter 
Replacing the decalcification cartridge.

Device switches off automatically

Run time for the decalcification cartridge has expired

Insert the new decalcification cartridge and reset the
maintenance indicator, see chapter Replacing the 
decalcification cartridge.

The RESET key was not pressed after replacement of 
the decalcification cartridge.

Press and hold the RESET key for 4 seconds after
inserting the decalcification cartridge, see chapter 
Replacing the decalcification cartridge.

Summary of Contents for SC 3

Page 1: ...SC 3 EasyFix SC 3 EasyFix Premium 59685480 10 20 English 5 15...

Page 2: ...A 2...

Page 3: ...B C D E F G H I J K L M 3...

Page 4: ...N O P Q R S 4...

Page 5: ...and beware of third parties in particular children when work ing with the device Only peo ple who have been instructed on how to use the device or have proven their ability to operate it and have been...

Page 6: ...the power supply and extension cable by running over it crush ing or yanking it or similar Pro tect the power supply cable from heat oil and sharp edges Un suitable electrical extension ca bles can be...

Page 7: ...mediately Only switch on the device when water is present in the steam boiler The device may other wise overheat see chapter Troubleshooting Accidents or damage due to the device falling over Before a...

Page 8: ...ur dealer with the purchase receipt or the next authorised customer service site See overleaf for the address Safety devices CAUTION Missing or modified safety devices Safety devices are provided for...

Page 9: ...second extension tube onto the first extension tube The connection pipes are connected Illustration J 5 Push the accessory and or the floor nozzle onto the free end of the extension tube Illustration...

Page 10: ...light nozzle to each extension tube 3 Fasten the large round brush to the spotlight nozzle 4 Connect the small round brush and nozzles to the medium sized mount for accessories 5 Hang the floor nozzle...

Page 11: ...steam pri or to use Note Detergent residue or care emulsions on the surface to be cleaned can lead to streaks during steam cleaning which will disappear however once these have been used several time...

Page 12: ...s off automatically in order to prevent device damage Inserting the decalcification cartridge ATTENTION Device damage There is a risk of damage to the device if the used de calcification cartridge is...

Page 13: ...Service WARNING Risk of electric shock and burns Trying to eliminate faults while the appliance is connect ed to the mains or has not yet cooled down is always dangerous Remove the mains plug Allow t...

Page 14: ...class IPX4 Protection category I Performance data Heating capacity W 1600 Maximum operating pressure MPa 0 35 Heating up time Seconds 30 Continuous steaming g min 40 Maximum steam blast g min 100 Fill...

Page 15: ...1 EasyFix SC 3 SC 3 1 2 3 110V 5 4 30 6 I 0 7 0 1 3 1x 4 II 7 14 1 3 2 5 2x III 14 2 1 2 5 3 8 3x IV 21 3 8 4x 1910 02 89780837 Reset 2 Reset Reset Reset...

Page 16: ...2 Reset 3 1 2 3 4 5 6 7 8 9 10 95 11 12 13 14 15 16 17 18 19 20 21 22 23...

Page 17: ...3 A J A B C D E F G H I J SC 3 EasyFix Premium 1 2 3 4 5 6 7 8 9 10 ON x2 x2 2 863 264 0 2 863 025 0 2 863 243 0 2 863 022 0 2 863 159 0 2 863 233 0 2 863 259 0...

Page 18: ...4 11 OFF 12 13 14 x 2 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 x 2 30 31 32 33 x 1 34 x 2 35 36 1 2 3 ON 30 20 OFF...

Page 19: ...5 G H 2 863 018 0 Reset 4 30 1 2 3 4 Reset Reset 4...

Page 20: ...6 Reset Reset 4 110 V 60 Hz 1600 W 3 5 Bar 30 40g mm 360 x 236 x 252 3 2 Kg 1 L SC 3 EasyFix 2020 V1...

Page 21: ......

Page 22: ...www kaercher com dealersearch Alfred K rcher SE Co KG Alfred K rcher Str 28 40 71364 Winnenden Germany Tel 49 7195 14 0 Fax 49 7195 14 2212...

Reviews: