a Place the floor cleaning cloth with the hook and 

loop fastener strips pointing upwards on the floor.

b Place the floor nozzle onto the floor cleaning 

cloth, applying slight pressure.

Illustration K

The floor cleaning cloth will stick to the floor nozzle 

of its own accord due to the hook and loop fastener.

Removing the floor cleaning cloth

1. Place one foot on the bottom corner of the floor 

cleaning cloth and lift the floor nozzle up.

Illustration K

Note

Initially, the floor cleaning cloth's hook and loop fastener 
strip is very strong and cannot be removed from the 
floor nozzle easily. After the floor cleaning cloth has 
been used several times and washed, it is easier to re-
move from the floor nozzle and it has reached the opti-
mum adhesion.

Parking the floor nozzle

1. Hang the floor nozzle in the park bracket during 

breaks in work.

Illustration N

Care and service

Descaling the steam boiler 

Note

Descaling the steam boiler is not required if commer-
cially available distilled water is used. 

Note

Since the lime becomes caked on the appliance, we 
recommend descaling the appliance as specified in the 
table (BF=boiler fillings) based on the number of times 
the steam boiler is filled.

Note

Your water board or municipal utilities authority can pro-
vide information on hardness of tap water.

ATTENTION

Damaged surfaces

The descaler may corrode sensitive surfaces.
Fill and empty the appliance carefully. 

1. Switch off the device, see chapter 

 Switch off the ap-

pliance

.

2. Allow the device to cool down.

3. Unscrew the safety lock.

4. Drain the water completely out of the steam boiler.

Illustration P

ATTENTION

Appliance damage due to descaler

An unsuitable descaler and incorrect dosing of the des-
caler may damage the appliance.
Only use KÄRCHER descaler.
Use 2 dosing units of the descaler for 1.0 l of water.

5. Apply descaler solution to the descaler according to

the details.

6. Fill the descaler solution into the steam boiler. Do 

not seal the steam boiler.

7. Allow the descaler solution to take effect for 

approx. 8 hours.

8. Drain descaler solution completely out of the steam 

boiler.

9. Repeat the descaling process if necessary.

10. Rinse the steam boiler 2-3 times with cold water in 

order to drain all the descaler solution residue.

11. Drain the water completely out of the steam boiler.

Illustration P

Care of accessories

(Accessories - depending on scope of delivery)

Note

The micro fibre cloths are not suitable for dryer.

Note

When washing the cloths, observe the instructions on 
the washing tag. Do not use any liquid softeners as this 
will affect the ability of the cloths to pick up dirt.

1. Wash the floor cleaning cloths and covers at a max. 

temperature of 60 °C in the washing machine.

Troubleshooting guide

Malfunctions often have simple causes that you can 

remedy yourself using the following overview. When in 

doubt, or in the case of malfunctions not mentioned 

here, please contact your authorised Customer Service.

WARNING

Risk of electric shock and burns

Trying to eliminate faults while the appliance is connect-
ed to the mains or has not yet cooled down is always 
dangerous. 
Remove the mains plug.
Allow the appliance to cool down.

Reduced steam quantity

The steam boiler is scaled.

Descale the steam boiler.

No steam

No water in the steam boiler

Refill water, see Chapter 

 Refilling water

.

The steam lever cannot be pressed

The steam lever is locked with the child lock.

Set the child lock (selector switch for steam volume) 

to the front.

The steam lever is released.

Long heating-up time

The steam boiler is scaled.

Descale the steam boiler.

High water egress

The steam boiler is too full.

Press the steam gun until a little water comes out.

Hardness range

°dH

mmol/l

KF

I

soft

0-7

0-1.3

55

II

Medium

7-14

1.3-2.5

45

III

Hard

14-21

2.5-3.8

35

IV

Very hard

>21

>3.8

25

Summary of Contents for SC 2 Deluxe EasyFix

Page 1: ...SC 2 Deluxe EasyFix Premium 59684960 02 22 Operating Instructions Please read the operating instructions carefully before using the unit...

Page 2: ...10 11 12 13 14 24 25 20 16 15 19 21 22 23 8 9 1 2 3 4 7 6 17 18 26 27 5 29 28 A 2...

Page 3: ...B C D 6 5 min E F G 1 2 H I J K 1 2 L M 3...

Page 4: ...N O P 4...

Page 5: ...are connected to the mains power Use a receptacle for fill ing Do not use the d in swimming pools which contain water The mains plug and extension cable connec tion must not be in water Do not clean o...

Page 6: ...er service only ATTENTION Do not fill with any cleaning agents or other supplements Do not use vinegar or similar agents Descaling the steam boiler CAUTION Never screw the safety lock onto the device...

Page 7: ...mum amount of equipment is described in these operating instructions Depending on the model used there are differences in the scope of delivery see packaging For the illustrations refer to the graphic...

Page 8: ...The device is ready for use Switch off the appliance 1 Pull the mains plug out of the socket 2 Press the steam lever until no more steam flows out Illustration M The steam boiler is depressurised 3 S...

Page 9: ...e surfaces It is not suitable for cleaning sensitive surfaces 1 Fit the round brush to the spotlight nozzle Illustration H Round brush large The large round brush is suitable for cleaning large rounde...

Page 10: ...the descaler for 1 0 l of water 5 Apply descaler solution to the descaler according to the details 6 Fill the descaler solution into the steam boiler Do not seal the steam boiler 7 Allow the descaler...

Page 11: ...ion class IPX4 Protection category I Performance data Heating capacity W 1500 Maximum operating pressure MPa 0 32 Heating up time Min utes 6 5 Continuous steaming g min 40 Maximum steam blast g min 10...

Page 12: ...e Meinung Rate your product and tell us your opinion valuer votre produit et dites nous votre opinion Rese e su producto y d ganos su opini n www kaercher com welcome www kaercher com dealersearch Alf...

Reviews: