Operations
Valve Operations
With all tanks full, you have the option of drawing water from the two outer tanks, the two inner tanks or all four
tanks.
OPTION 1: To draw water from the outer tanks set the outer tank valve to the "ON" position and the inner tank valve
to the "Off" position. Set the bypass valve to the outer tank position.
OPTION 2: To draw water from the inner tanks set the outer tank valve to the "OFF" position and the inner tank
valve to the "ON" position. Set the Bypass valve to the inner tank position.
OPTION 3:
To draw water from all the tanks set the outer and inner tank valves to the "ON" position. The bypass
valve can be in the inner or outer tank position
.
Landa ECOS 7000 Operator’s Manual 9.801-316.0 - E
ON
OFF
ON
OFF
INNER VALVE
OUTER VALVE
BYPASS
VALVE
FROM INNER
TANKS
FROM OUTER TANKS
TO
PUMP
FROM UNLOADER
(BYPASS OUTLET)
TO
INNER
TANKS
TO
OUTER
TANKS