Install the batteries
Note:
When using batteries with a liquid
electrolyte coat the battery terminals
adequately with terminal grease to
protect them from corrosion!
!
Removing rear trim panel
!
Screw out fastening screws of
unit cover
!
Open unit cover
!
Place batteries into unit
!
Grease posts and connect them
with the enclosed connection
wires (
1
,2)
Connect connection wires
to battery
!
Connect supplied connection
wire to the still vacant battery
terminals
—
First connect the wire identified
with red (
1
) with the positive
terminal post
—
Then connect the black wire (2)
to the negative terminal post
Note!
The batteries are already mounted
in the Package versions.
It is only necessary to connect the
connection wires to the vacant
battery posts as described above.
!
Close unit cover
!
Screw the cover’s fastening
screw back in
!
Mount rear trim panel
Warning!
Charge the batteries prior to starting
to operate the unit!
Charge the battery
Note:
The recommended battery chargers
are electronically controlled and
independently complete the
charging process.
On average charging time is
10-15 hours.
During charging all machine
operations are automatically
interrupted.
On-Board battery charger
(Package version)
!
Plug power cord of the integrated
battery charger into plug socket
The charging process can be
checked at the charge indicator
1
. Yellow LED is lit = battery is
being charged
2. Green LED is lit = the battery is
fully charged
3. Red LED is lit = problem with
battery charger/battery
!
Disconnect the unit from the
mains after charging
External battery charger
Only use battery chargers
recommended by the manufacturer
!
Removing rear trim panel
!
Screw out fastening screws of
unit cover
!
Open unit cover
!
Disconnect connection plug of
the battery connection wire and
connect it with the charge wire
!
Plug in power plug of the battery
charger
—
It is essential to observe the
instructions provided by the
manufacturerer of the charging
unit
!
Switch off battery charger upon
completion of charging and
disconnect it from the mains
!
Reconnect plug and socket
connection with the power cord
!
Close unit cover
!
Screw the cover’s fastening
screw back in
!
Mount rear trim panel
Summary of Contents for KMR 90/45 R
Page 1: ...5 960 443 F2002165 03 06 www kaercher com KMR 90 45 R 1 405 101 1 405 111...
Page 116: ...KM 90 45 R KM 90 45 R KM 90 45 R KM 90 45 R 116 VDE 0701...
Page 117: ...KM 90 45 R KM 90 45 R KM 90 45 R KM 90 45 R 117 K rcher 91 157 E 12 12...
Page 119: ...KM 90 45 R KM 90 45 R KM 90 45 R KM 90 45 R 119 0 1 A 1 M F R 0 1 M...
Page 120: ...KM 90 45 R KM 90 45 R KM 90 45 R KM 90 45 R 120 45 mm 0 K...
Page 126: ...KM 90 45 R KM 90 45 R KM 90 45 R KM 90 45 R 126 40 50 mm 0 0 0...
Page 127: ...KM 90 45 R KM 90 45 R KM 90 45 R KM 90 45 R 127 M8x100 M8x100 50 70 mm 0 10 15 mm...
Page 128: ...KM 90 45 R KM 90 45 R KM 90 45 R KM 90 45 R 128 10 15 mm 3 mm 0 3 mm K 4...
Page 129: ...KM 90 45 R KM 90 45 R KM 90 45 R KM 90 45 R 129 1 2 3 4 0 0 1 K rcher K rcher K rcher...
Page 224: ...KM 90 45 R 224...