background image

English

 15

Illustrations on Page 2

Illustration 
Mount loose parts delivered with appliance 
prior to start-up.

According to the applicable regula-
tions, the appliance must never be 
used on the drinking water supply 
without a system separator. Use a 
suitable system separator manufactured by 
KÄRCHER; or, as an alternative, a system 
separator as per EN 12729 Type BA. Water 
flowing through a system separator is consid-
ered non-drinkable.

Note:

 Impurities in the water can damage the 

high-pressure pump and accessories. For 
protection, the use of the KÄRCHER water fil-
ter (optional accessory, order no. 4.730-059) 
is recommended.

Observe regulations of water supplier.
For connection values, see type plate/techni-
cal data.

!

Use a fibre-reinforced water hose (not in-
cluded) with a standard coupling. (Mini-
mum diameter 1/2 inch (13 mm), 
minimum length 7.5 m).

Illustration 

!

Screw the coupling element (supplied) to 
the water connection on the appliance.

!

Push the water supply hose onto the cou-
pling unit, then connect it to the water sup-
ply.

Illustration 

!

Fill fuel tank with heating oil or diesel. 

m

Danger

Risk of explosion! Only refill diesel oil or light 
fuel oil. Unsuitable fuels, e.g. petrol, are not to 
be used.

Caution

Below exterior temperatures of 6°C, only Win-
ter diesel must be used, as there might be 
problems with operating due to the flocking of 
diesel components.

The fuel tank must be sufficiently filled, even 
during cold water operation. If the fuel tank is 
empty, the fuel pump will run dry and be de-
stroyed.

Illustration 

!

Connect the high pressure hose to the 
high pressure connection of the appli-
ance.

Illustration 

!

Push the spray lance into the trigger gun 
and fasten it by turning it through 90°.

Illustration 

!

Completely open the water tap.

Illustration 

!

Insert the mains plug into the socket. 

Important instruction

: Black water can build 

up in the heating coil if the appliance is not 
used for extended periods of time. Therefore, 
we recommend rinsing the appliance first 
without the spray lance attached prior to star-
tup, until clear water is emitted from the hand 
spray gun. For this, turn the appliance on us-
ing the appliance switch. Discharge the water 
from the rinsing process into the public sewer 
system.

n

Danger

The trigger gun is subjected to a recoil force 
when the water jet is discharged. Make sure 
that you have a firm footing and are also hold-
ing the trigger gun and spray lance firmly.

Caution

Dry runs lasting longer than two minutes lead 
to damages to the high pressure pump. If the 
appliance does not build up pressure within 
two minutes, switch it off and proceed as in-
structed in the Chapter "Help with faults".

Illustration 

!

Turn on the appliance “I/ON”.

Illustration 

!

For hot water operation, also switch on 
the appliance switch for burner operation.

Important instruction

: If there is air in 

the fuel line (with new appliances or after 
operating with an empty tank), it can take 
up to 5 minutes until the burner starts. 

Illustration 

!

Unlock the lever on the trigger gun.

Before Startup

Water supply

Water supply from mains

Start up

Cold water/hot water operation

Summary of Contents for K 855 HS

Page 1: ...ederlands 35 Espa ol 43 Portugu s 51 Dansk 59 Norsk 67 Svenska 75 Suomi 83 91 T rk e 99 cc 107 Magyar 115 e tina 123 Sloven ina 131 Polski 139 Rom ne te 147 Sloven ina 155 Hrvatski 163 Srpski 171 0123...

Page 2: ...2...

Page 3: ...e proper recycling of old appliances Please dispose your old applianc es using appropriate collection systems Notes about the ingredients REACH You will find current information about the in gredients...

Page 4: ...bserved when cleaning with the jet Never draw in fluids containing solvents or undiluted acids and solvents This in cludes petrol paint thinner and heating oil The spray mist thus generated is high ly...

Page 5: ...o be used with detergents which are supplied or rec ommended by the manufacturer The use of other detergents or chemicals may compromise the safety of the appliance Caution Safety devices protect the...

Page 6: ...r detergent 5 Mains cable with mains plug 6 Water connection with integrated sieve 7 Coupling element for water connection 8 Trigger gun 9 Lock trigger gun 10 High pressure connection 11 Storage for t...

Page 7: ...he fuel tank is empty the fuel pump will run dry and be de stroyed Illustration Connect the high pressure hose to the high pressure connection of the appli ance Illustration Push the spray lance into...

Page 8: ...e appliance while there is no pressure in the system After cleaning procedures during hot water operation run the appliance with cold water for another to cool off the boiler system or the hot high pr...

Page 9: ...zzle Remove dirt and debris from the nozzle bore using a needle and rinse through with water from the front Check water flow quantity Slight leakage from the appliance pump is normal If the leakage in...

Page 10: ...lass IP X5 Water connection Max feed temperature 30 C Min feed volume 10 I min Max feed pressure 0 6 MPa Performance data Working pressure 11 MPa Max permissible pressure 13 MPa Water flow rate 6 7 I...