Do not operate the appliance at tempera-
tures below 0 °C.

 

Observe a distance of at least 30 cm when 
using the jet to clean painted surfaces to 
avoid damaging paintwork.

 

Never leave the appliance unattended 
when it is in operation.

 

Make sure that the power cable or exten-
sion cables are not damaged by running 
over, pinching, dragging or similar. Pro-
tect the power cable from heat, oil, and 
sharp edges.

 

All current-conducting parts in the working 
area must be protected against jet water.

 

The appliance may only be connected to 
an electrical supply which has been in-
stalled in accordance with IEC 60364.

 

The appliance may only be connected to 
alternating current. The voltage must cor-
respond with the type plate on the appli-
ance.

 

The maximum tolerable mains impedance 
at the electrical contact point (see Techni-
cal Data) must not be exceeded.

 

For safety reasons, we recommend that 
you operate the appliance only via a 
earth-leakage circuit breaker (max. 
30 mA).

 

Cleaning operations which produce oily 
waste water, e.g. engine washes, under-
body washes, may only be carried out us-
ing washing stations equipped with an oil 
separator.

 

This appliance was designed to be used 
with detergents which are supplied or rec-
ommended by the manufacturer. The use 
of other detergents or chemicals may 
compromise the safety of the appliance.

Caution

Safety devices protect the user and must not 
be modified or bypassed.

The appliance switch prevents unintentional 
operation of the appliance.

This lock locks the lever of the trigger gun and 
prevents the inadvertent start of the appli-
ance.

The overflow valve prevents the permissible 
working pressure from being exceeded. 
If the lever on the trigger gun is released the 
pressure switch turns off the pump, the high-
pressure jet ist stopped. If the lever is pulled 
the pump is turned on again.

The water shortage safeguard will shut the 
burner off as soon as the pump pressure falls 
below 25 bar.

If the permitted working temperature is ex-
ceeded, the safety thermostat switches off the 
pump.

The high pressure hose is specially construct-
ed with reinforced walls to handle water pres-
sure up to 13 MPa (1900 psi) - it can be easily 
damaged and should be stored carefully.

 

Do not kink.

 

Do not drive vehicles over the hose.

 

Do not expose the hose to sharp edges or 
corners.

Misuse will lead to ballooning or premature 
failure and will invalidate warranty.

Safety Devices

Power switch

Lock trigger gun

Overflow valve with pressure switch

Water shortage safeguard

Safety thermostat

High pressure hose

Summary of Contents for K 855 HS

Page 1: ...ederlands 35 Espa ol 43 Portugu s 51 Dansk 59 Norsk 67 Svenska 75 Suomi 83 91 T rk e 99 cc 107 Magyar 115 e tina 123 Sloven ina 131 Polski 139 Rom ne te 147 Sloven ina 155 Hrvatski 163 Srpski 171 0123...

Page 2: ...2...

Page 3: ...e proper recycling of old appliances Please dispose your old applianc es using appropriate collection systems Notes about the ingredients REACH You will find current information about the in gredients...

Page 4: ...bserved when cleaning with the jet Never draw in fluids containing solvents or undiluted acids and solvents This in cludes petrol paint thinner and heating oil The spray mist thus generated is high ly...

Page 5: ...o be used with detergents which are supplied or rec ommended by the manufacturer The use of other detergents or chemicals may compromise the safety of the appliance Caution Safety devices protect the...

Page 6: ...r detergent 5 Mains cable with mains plug 6 Water connection with integrated sieve 7 Coupling element for water connection 8 Trigger gun 9 Lock trigger gun 10 High pressure connection 11 Storage for t...

Page 7: ...he fuel tank is empty the fuel pump will run dry and be de stroyed Illustration Connect the high pressure hose to the high pressure connection of the appli ance Illustration Push the spray lance into...

Page 8: ...e appliance while there is no pressure in the system After cleaning procedures during hot water operation run the appliance with cold water for another to cool off the boiler system or the hot high pr...

Page 9: ...zzle Remove dirt and debris from the nozzle bore using a needle and rinse through with water from the front Check water flow quantity Slight leakage from the appliance pump is normal If the leakage in...

Page 10: ...lass IP X5 Water connection Max feed temperature 30 C Min feed volume 10 I min Max feed pressure 0 6 MPa Performance data Working pressure 11 MPa Max permissible pressure 13 MPa Water flow rate 6 7 I...