Specifications

Power connection

Voltage

 (1~50 Hz) 230-240 V

Connected load

2,1 kW

Mains fuse (slow-blow)

10 A

Protective class

I

Protection class

IP X5

Water connection

Max. feed temperature

40 °C

Min. feed volume

10 l/min

Max. feed pressure

0,6 MPa

Performance data

Working pressure

12,5 MPa

Max. permissible pressure

13 MPa

Water flow rate

7,5 l/min

Detergent flow rate

0-0,2 l/min

Recoil force of trigger gun

20 N

Hand-arm vibration 
(ISO 5349)

0,8 m/s

2

Sound pressure level 
L

pA

 (EN60704-1)

78 dB(A)

Sound power level 
L

WA

 (2000/14/EG)

92 dB(A)

Dimensions

Length

400 mm

Width

365 mm

Height

900 mm

Weight

16,2 kg

Customer Service

Summary of Contents for K 5.86 M

Page 1: ...Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them K 5 85 M 5 960 847 0 08 07...

Page 2: ...2 Assembly see page 10...

Page 3: ...utors We will re pair possible faults on your unit free of charge within the warranty period insofar as the faults are caused by material defects or defective workmanship Guarantee claims should be ad...

Page 4: ...losive and poi sonous Do not use acetone undiluted acids and solvents as they are aggres sive towards the materials from which the appliance is made Warning Check the high pressure hose for dam age be...

Page 5: ...the appliance The minimum fuse rating required at the socket outlet is 10 A slow blow To avoid accidents due to electrical faults we recommend the use of sock ets with a line side current limiting ci...

Page 6: ...tion mode the K rcher suction hose with integrated fil ter should be used instead special ac cessory order no 4 440 238 and suspended inside the water butt Use the K rcher water filter to protect the...

Page 7: ...y catch to secure the trigger gun lever During longer breaks more than 5 min utes also turn the appliance off using the ON OFF switch If detergent has been added Suspend detergent suction hose in a co...

Page 8: ...e mains plug before care and mainte nance work Warning Repair works may only be performed by the authorized customer service Appliance does not start Check whether the voltage indicated on the type pl...

Page 9: ...ction class IP X5 Water connection Max feed temperature 40 C Min feed volume 10 l min Max feed pressure 0 6 MPa Performance data Working pressure 12 5 MPa Max permissible pressure 13 MPa Water flow ra...

Page 10: ...10 English Assembly...

Page 11: ...English 11 Spare Parts...

Page 12: ......

Reviews: