background image

English

 17

You can rectify minor faults yourself with the help of the 
following overview. 
If in doubt, please consult the authorized customer ser-
vice.

DANGER

Risk of electric shock.

Prior to all work on the appliance, switch off the ap-
pliance and pull the power plug.

Pull on the lever of the trigger gun; the device will 
switch on.

Check whether the voltage indicated on the type 
plate corresponds to the voltage of the mains sup-
ply.

Check the mains connection cable for damages.

Check setting at the spray lance.

Check water supply for adequate delivery rate.

Pull out the sieve in the water connection using flat-
nose pliers and clean under running water.

Appliance ventilation: Switch the appliance on with 
the high-pressure hose detached and operate 
(max. 2 minutes) until the water exits the high-pres-
sure connection without bubbles. Switch off appli-
ance and reconnect high-pressure hose.

Clean high-pressure nozzle: Remove dirt and de-
bris from the nozzle bore, using a needle and rinse 
through with water from the front.

Check water flow quantity.

Slight leakage from the appliance pump is normal. 
If the leakage increases contact the authorized 
customer service.

Use spray lance with pressure regulation (Vario 
Power).
Turn the spray lance as far as it will go in the direc-
tion of "SOFT".

Clean the detergent suction hose filter.

Check the detergent suction hose for kinks.

The warranty terms published by the relevant sales 
company are applicable in each country. We will repair 
potential failures of your appliance within the warranty 
period free of charge, provided that such failure is 
caused by faulty material or defects in manufacturing. In 
the event of a warranty claim please contact your dealer 
or the nearest authorized Customer Service center. 
Please submit the proof of purchase.
Addresses can be found under:

www.kaercher.com/dealersearch

Troubleshooting

Appliance is not running

Pressure does not build up in the appliance

Strong pressure fluctuations

Appliance is leaking

No detergent infeed

Warranty

Technical specifications

Electrical connection

Voltage

220-240
1~50-60

V
Hz

Power consumption

6 A

Protection class

IPX5

Protective class

II

Mains fuse (slow-blow)

10 A

Water connection

Max. feed pressure

1,2 MPa

Max. feed temperature

40 °C

Min. feed volume

8 I/min

Performance data

Working pressure

8 MPa

Max. permissible pressure

12 MPa

Water flow rate

5,5 I/min

Max. flow rate

6,3 I/min

Detergent flow rate

0,3 I/min

Recoil force of trigger gun

12 N

Dimensions and weights

Length

279 mm

Width

275 mm

Height

803 mm

Typical operating weight

7,0 kg

Values determined as per EN 60335-2-79

Hand-arm vibration value
Uncertainty K

<2,5

0,3

m/s

2

m/s

2

Sound pressure level L

pA

Uncertainty K

pA

74

3

dB(A)
dB(A)

Sound power level L

WA

 + Uncertainty 

K

WA

90 dB(A)

Subject to technical changes.

Summary of Contents for K 3

Page 1: ...cc 4 English 12 Register your product www kaercher com welcome 001 K 3 59786110 10 21...

Page 2: ...2...

Page 3: ...3...

Page 4: ...4 cc 60 IEC 60364 30 1 10 1 5 2 10 30 2 5 2 4 6 6 6 7 7 7 8 9 9 9 10 10 10 U 11...

Page 5: ...cc 5 30 0 C EN 12729 BA...

Page 6: ...6 cc FFP 2 REACH www kaercher com REACH K RCHER www kaercher com...

Page 7: ...cc 7 1 2 0 OFF I ON 0 I 3 4 5 P 6 7 8 9 C 10 11 12 13 14 15 16 17 18 Vario Power SOFT HARD 19 C 20 21 22 K RCHER 4 730 059 23 1 2 13 7 5...

Page 8: ...8 cc 2 2 30 90 I ON I Vario Power SOFT 90 90 5 0 OFF 0 1 0 OFF 0...

Page 9: ...cc 9 1 2 Vario Power SOFT...

Page 10: ...10 cc www kaercher com dealersearch 220 240 1 50 60 V Hz 6 A IPX5 II 10 1 2 40 C 8 8 12 5 5 6 3 0 3 12 279 275 803 7 0 EN 60335 2 79 K 2 5 0 3 2 2 KpA 74 3 LWA KWA 90...

Page 11: ...195 14 2212 U 1 601 xxx U 2000 14 2014 30 EC 2006 42 EC 2009 127 EC 2011 65 C EN 60335 1 EN 60335 2 79 EN 62233 2008 EN 55014 1 2017 EN 55014 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 EN IEC 63000 20...

Page 12: ...current device max 30 mA An unsuitable electrical extension cable can be hazardous Only use an electrical extension cable which has been approved and labelled for this pur pose and has an adequate ca...

Page 13: ...sified as drinking water High pressure hoses fixtures and couplings are important for the safety of the appliance Only use high pressure hoses fixtures and couplings rec ommended by the manufacturer W...

Page 14: ...gun 16 Clamp for high pressure hose 17 High pressure hose 18 Spray lance with pressure regulation Vario Power Carrying out the most common cleaning tasks The working pressure can be continuously in c...

Page 15: ...t least 30 cm when using the jet for cleaning painted surfaces to avoid damage ATTENTION Car tyres paint or sensitive surfaces such as wood should not be cleaned with the dirt blaster as there is a ri...

Page 16: ...the quick coupling for the high pressure hose toward the rear and disconnect the high pressure hose from the appliance Press the disconnect on the trigger gun and re move the high pressure hose from...

Page 17: ...he detergent suction hose filter Check the detergent suction hose for kinks The warranty terms published by the relevant sales company are applicable in each country We will repair potential failures...

Page 18: ...rvisor S Reiser Alfred K rcher SE Co KG Alfred K rcher Stra e 28 40 71364 Winnenden Germany Tel 49 7195 14 0 Fax 49 7195 14 2212 EU Declaration of Conformity Product High pressure cleaner Type 1 601 x...

Page 19: ...19...

Page 20: ...y aproveche de muchas ventajas Bewerten Sie Ihr Produkt und sagen Sie uns Ihre Meinung Rate your product and tell us your opinion valuer votre produit et dites nous votre opinion Rese e su producto y...