16
English
DANGER
Risk of electric shock.
Prior to all work on the appliance,
switch off the appliance and pull the
power plug.
Push the lever of the trigger gun, the de-
vice will switch on.
Check whether the voltage indicated on
the type plate corresponds to the volt-
age of the mains supply.
Check the mains connection cable for
damages.
Completely open the water tap.
Appliance ventilation: Switch the appli-
ance on with the high-pressure hose
detached and operate (max. 2 minutes)
until the water exits the high-pressure
connection without bubbles. Switch off
appliance and reconnect high-pressure
hose.
Pull out the sieve in the water connec-
tion using flat-nose pliers and clean un-
der running water.
Clean high-pressure nozzle: Remove
dirt and debris from the nozzle bore, us-
ing a needle and rinse through with wa-
ter from the front.
Check water flow quantity.
Slight leakage from the appliance pump
is normal. If the leakage increases con-
tact the authorized customer service.
Only use original accessories and spare
parts, they ensure the safe and trouble-free
operation of the device.
For information about accessories and
spare parts, please visit www.kaercher.com.
The warranty terms published by the rele-
vant sales company are applicable in each
country. We will repair potential failures of
your appliance within the warranty period
free of charge, provided that such failure is
caused by faulty material or defects in man-
ufacturing. In the event of a warranty claim
please contact your dealer or the nearest
authorized Customer Service centre.
Please submit the proof of purchase.
Addresses can be found under:
www.kaercher.com/dealersearch
Call:
01-800-024-13-13
for help or visit our
website:
www.karcher.com.mx
Troubleshooting
Appliance is not running
Pressure does not build up in the
appliance
Strong pressure fluctuations
Appliance is leaking
Accessories and Spare Parts
Warranty
Customer Support Mexico
Technical specifications
Electrical connection
Voltage
127
1~50-60
V
Hz
Power consumption
10 A
Protection class
IPX5
Protective class
II
Water connection
Max. feed pressure
1,2 MPa
Max. feed temperature
40 °C
Min. feed volume
6 l/min
Performance data
Working pressure
7,4 MPa
Max. permissible pressure
11,0 MPa
Water flow rate
4,5 I/min
Max. flow rate
4,7 I/min
Recoil force of trigger gun
9 N
Dimensions and weights
Length
280 mm
Width
182 mm
Height
390 mm
Weight, ready to operate
with accessories
4,5 kg
Subject to technical changes.