background image

English

Mount loose parts delivered with appliance 
prior to start-up.

Illustrations on Page 5

Illustration 

Attach the carrying handle.

Illustration 

Pull out the clamp for the high-pressure 
hose from the trigger gun (e.g. with a 
small screwdriver).

Illustration 

Connect high pressure hose to trigger 
gun.

Push the clamp in until it locks. Check 
the secure connection by pulling on the 
high-pressure hose.

According to the applicable regula-
tions, the appliance must never be 
used on the drinking water supply 
without a system separator. Use a 
suitable system separator manufactured by 
KÄRCHER; or, as an alternative, a system 
separator as per EN 12729 Type BA. Water 
flowing through a system separator is con-
sidered non-drinkable. 

Caution

Always connect the system separator to the 
water supply, never directly to the appliance!

Note:

 Impurities in the water can damage 

the high-pressure pump and accessories. 
For protection, the use of the KÄRCHER 
water filter (optional accessory, order no. 
4.730-059) is recommended.

Observe regulations of water supplier.
For connection values, see type plate/tech-
nical data.

Use a fibre-reinforced water hose (not 
included) with a standard coupling. 
(Minimum diameter 1/2 inch (13 mm), 
minimum length 7.5 m).

Screw the coupling element to the wa-
ter connection on the appliance.

Push the water supply hose onto the 
coupling unit, then connect it to the wa-
ter supply.

Caution

Dry runs lasting longer than two minutes 
lead to damages to the high pressure 
pump. If the appliance does not build up 
pressure within two minutes, switch it off 
and proceed as instructed in the Chapter 
"Troubleshooting".

Connect the high pressure hose to the 
high pressure connection of the appli-
ance.

Push the spray lance into the trigger 
gun and fasten it by turning it through 
90°.

Completely open the water tap.

Insert the mains plug into the socket. 

Turn on the appliance “I/ON”.

Danger

The trigger gun is subjected to a recoil force 
when the water jet is discharged. Make 
sure that you have a firm footing and are 
also holding the trigger gun and spray lance 
firmly.

Unlock the lever on the trigger gun.

Pull on the lever of the trigger gun; the 
device will switch on.

Note:

 Release the lever of the trigger gun; 

the device will switch off again. High pres-
sure remains in the system.

For normal cleaning tasks.
Not suitable for use with detergents.

Operation

Before Startup

Water supply

Water supply from mains

Start up

Operation

Spray lance with high pressure nozzle

Summary of Contents for K 1100

Page 1: ...w w w kaer cher com r egi st er and w i n Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them 59651430 10 13 K 1 100...

Page 2: ...i mals live electrical equipment or at the appliance itself Pro tect the appliance against frost The packaging material can be recy cled Please do not place the packag ing into the ordinary refuse for...

Page 3: ...ance of at least 30 cm is observed when clean ing with the jet Risk of explosion Do not spray flammable liquids Never draw in fluids containing solvents or undiluted acids This includes petrol paint t...

Page 4: ...wer cable from heat oil and sharp edges All current conducting parts in the work ing area must be protected against jet water The appliance may only be connected to an electrical supply which has been...

Page 5: ...handle 5 Coupling element for water connection 6 Connection for water supply with filter 7 Detergent suction hose with sieve 8 Mains cable with mains plug 9 Trigger gun 10 Lock trigger gun 11 Clamp f...

Page 6: ...r hose not included with a standard coupling Minimum diameter 1 2 inch 13 mm minimum length 7 5 m Screw the coupling element to the wa ter connection on the appliance Push the water supply hose onto t...

Page 7: ...appliance off using the 0 OFF switch Caution Only separate the high pressure hose from the trigger gun or the appliance while there is no pressure in the system After working with detergent suspend d...

Page 8: ...supply max 1 minute and wait until no more water exits at the high pressure connection Turn off the appliance Store the appliance and the entire ac cessories in a frost free room Danger Turn off the a...

Page 9: ...e through with wa ter from the front Check water flow quantity Slight leakage from the appliance pump is normal If the leakage increases con tact the authorized customer service Detach spray lance fro...

Page 10: ...10 English Notes...

Page 11: ...English 11 Spare parts...

Page 12: ...http www kaercher com dealersearch...

Reviews: