– 12
Specifications
IVS
IVS 100/40 M
IVS 100/55 M
IVS 100/75 M
Type of protection
IPX4
Container capacity
100
Voltage
400 V 3~50 Hz
Maximum allowed net impedance
0.400+j0.250
Ohm
0.156+j0.098
Ohm
0.400+j0.250
Ohm
Blower data
Power
4200 W
5500 W
7500 W
Power input (normal operation)
4750 W
6220 W
6080 W
Max. volume flow
220 m³/h
353 m³/h
373 m³/h
Suction power, max. negative pressure
15.4 kPa
24 kPa
30.5 kPa
Effective filter area
2.0 m²
2.0 m²
2.0 m²
Length x width x height
1202 x 686 x1465 mm
Cable length
8.2 m
Protective class
I
Power cord: Order No.
6.650-822.0
6.650-822.0
6.650-823.0
Mains cable: Type:
H07RN-F
5x2.5 mm²
Suction hose connection (C-DN/C-ID)
NW DN72
Nominal width of suction hose
DN 42/52
DN 42/52/72
Typical operating weight
142 kg
148 kg
165 kg
Storage temperature
-10...+40°C
Filter area
2.24 m
2
Values determined to EN 60335-2-69
Sound pressure level L
pA
75 dB(A)
77 dB(A)
73 dB(A)
Uncertainty K
pA
2 db (A)
Hand-arm vibration value
<2.5 m/s
2
Uncertainty K
0.2 m/s
2
26
EN