– 7
On completion of wet vacuum cleaning:
Dry the filter. Clean the container with a
moist cloth and dry it off.
Vacuum and wipe the appliance inside
and outside with a damp cloth.
A pressure gauge showing the vacuum in-
side the device is located on the front of the
device. If the vacuum is greater than the
value given in the table, then the device
must be switched off and the filter cleaned.
Press the "Switch off appliance" switch.
Move the filter cleaning lever back and
forth several times, but 5 times at least.
If this cleaning does not bring about any im-
provement, then remove the filter and wash
it or replace it (see chapter "Replacing the
filter").
The appliances
IVS 100/40
IVS 100/55
IVS 100/75
are equipped with a radio receiver for the
remote control option.
The training time and operation are de-
scribed in the operating instructions of the
remote control.
Switch off the appliance using the On/
Off switch.
If necessary, dismantle the accessory
and rinse it with water and let dry.
Empty the vacuuming material contain-
er (refer chapter "Emptying vacuuming
material container").
Vacuum and wipe the appliance inside
and outside with a damp cloth.
On completion of wet vacuum cleaning:
Dry the filter. Clean the container with a
moist cloth and dry it off.
Switch off the appliance and secure it
using the parking brakes at the guide
rollers.
Unlock and lower the container.
Switch on device to avoid releasing
dangerous dusts.
Pull out the vacuuming material con-
tainer from the appliance using the han-
dle that has been provided for the pur-
pose.
Replace the dust bag (see chapter "Dis-
posal system").
Note
The vacuum material container can be lift-
ed by cranes at the handle. Maximum load
for crane transport: 50 kg.
Cleaning the device
Cleaning the filter
NW 42
NW 52
NW 72
IVS 100/40
10 kPa
7.5 kPa
--
IVS 100/55
20 kPa 18.0 kPa 10 kPa
IVS 100/75
28 kPa
24 kPa
13 kPa
Indicator lamps
Green indicator lamp
Lights up when the suction turbine is
running
Blink codes for training the remote con-
trol (see radio remote control)
Red indicator lamp
Lights if there is a rotary field fault.
Note:
Appliance is not running.
Exchange the poles at the appliance
plug.
Remote control
Shutting down
Emptying the vacuuming material
container
21
EN
Summary of Contents for IVS 100/40 M