Maintenance/Repair
28/49
Disassembly of the bag-type filter
NOTICE
Before starting work
remove the plug from the wall socket!
Suitable work gloves must
always
be worn when carrying out maintenance and service tasks,
in order to prevent injuries and soiling with contaminated substances
Respiratory protection (EN 149:2001)
Use protective glasses (acc. to DIN EN 166 1349-BT)
Use protective clothing (acc. to EN 13982-1)
•
Place drive unit on suitable basis in illustrated position,
•
Loosen clamping belt (41) and remove with the small baffle plate (40).
•
Take off clamping belt (19), observe correct seat during assembly.
•
Surface filters (46) remove and seal it in a bin liner.
•
Accumulated dirt on the clean air side with a damp cloth to remove
•
Install new filter surface (46) (see wear parts list).
Assembly occurs in the inverse order.