Initiation
14/49
Initiation
Only use with safety shoes (acc. to EN ISO 20345)
CAUTION
Connection to the electric mains
• Check that the industrial vacuum cleaner is in correct condition before commissioning.
• Before connecting the industrial vacuum cleaner to the mains, make sure that the voltage specified
on the typeplate matches the supply voltage.
• The industrial vacuum cleaner is set to clockwise rotating field at delivery.
• Connect the device cable plug to a socket installed with correct earthing. The industrial vacuum
cleaner must be switched off!
• Check correct connection between plug and socket.
• Only use industrial vacuum cleaners with mains cables in perfect condition (damaged cables can
cause electric shocks!).
• Regularly check the mains lead for damage, cracks or cable wear.
• Always use the plug to remove the mains lead from the socket (do not use the cable itself).
• When replacing the mains lead, always replace it with a type that matches the original lead.
• The mains lead may only be replaced by the manufacturer or its customer service department, or a
similarly qualified person.
WARNING
Before switching on, check:
that all filters are correctly adjusted;
that the collecting tank is correctly positioned beneath the filter unit and locked.
that the suction tube and accessories are correctly connected;
that the PE round bottom bag is inserted in the collecting tank.
Do not use with defective or absent filtration system!
Switching the suction system on and off at the control cabinet
In manual mode, the suction system is switched on and off via the ON/OFF button. In automatic mode
this is accomplished via a machine contact.
If the suction system does not function after it has been switched on, or runs in the wrong direction, it
must be switched off, the plug must be removed from the socket and the technical specialist staff must
be alerted.
Incorrect rotational direction
If the rotational direction is incorrect, drives with side-channel compressor convey the suction air in the
inverse direction, i.e. an air current is discharged from the raw air suction nozzle of the suction system.
The rotation monitoring prevents the wrong direction, the power is turned on. This is important if the
unit does inserted mains can not be operated.If this is the case, the suction system must be switched
off immediately, the mains plug removed from the mains socket and the technical personnel informed,
so that the phase conductors in the mains lead can be reversed.
Potential equalization conductors