Hydraulic System – Checking working pressures (continued)
1
Pressure-side connection
2
T-joint
3
Pressure line to control block, side
console
4
Testing set (special tool)
5
Hydraulic pump, side brushes and
debris container
Checking hydraulic pressure for side brushes
and debris container
–
Unscrew pressure line to control block (3)
from pressure-side connection (1).
–
Install T-joint (2) between pressure-side
connection (1) and pressure line (3).
–
Install testing set (4) on T-joint (2).
–
Start engine, and run at full throttle.
–
Raise side brush cylinders until they rest
against the stops.
–
With side brushes engaged and rotating, a
pressure of 60 to 80 bar must be indicated on
testing gauge.
–
For adjustment of pressure relief valve, refer
to page 51.