1 Label
2 RFID tag, behind the label
Note
Tag is an electronic component on the new square soften-
er bottle. The tag is located behind the bottle label. The tag
can be read and written on electronically.
Float tank
The float container is integrated in the chassis. It is located
on the right, under the liquid softener reservoir.
The swimmer reservoir supplies the pump evenly with wa-
ter. It is also used to separate the water inlet and the pump
and prevents detergent from entering the water supply line
in case of damage.
Swimmer valve
Water flows into the float container through the opened
float valve.
When the water level is rising, the float ball rises and clos-
es the float valve.
The float valve is adjusted permanently and must not be
readjusted.
1 Water inlet
2 Swimmer valve
3 Swimmer ball
4 Float tank
6.11 Swimmer tank