Read the fault memory in service mode at 70 (52/44)°C.
Every fault type is saved only once, together with the
passed hours since it has last occurred.
Advance with "SET".
OOOO end of the fault memory reached.
OOOO display of the software version.
7.46 Overview of a quick check of the device status
Overvoltage detected hours ago:
Low voltage range detected hours ago:
Excess current detected hours ago:
Current asymmetry detected hours ago:
Tripped winding protection motor detected hours ago:
2 minutes dry running detected hours ago:
Stuck water shortage safeguard detected hours ago:
Oil shortage in pump detected hours ago:
Leakage (10 short startups) detected hours ago:
Triggered exhaust gas thermostat detected hours ago:
Faulty temperature sensor for water detected in hours:
Flame sensor detects too little light hours ago:
Flame sensor detects light hours ago:
Reading error RFID electronics detected hours ago:
Summary of Contents for HDS 7/12 M
Page 14: ...14 English 5 906 432 0 Rev 00 06 15...
Page 60: ...60 English 5 906 432 0 Rev 00 06 15 6 29 Functional diagram vacuuming operation...
Page 125: ...English 5 906 432 0 Rev 00 06 15 125 Circuit diagram 0 089 021 0 HDS 7 12...
Page 126: ...126 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 089 025 0 HDS 8 18 HDS 9 18...
Page 128: ...128 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 088 952 0 HDS 10 20 HDS 12 18...
Page 130: ...130 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 089 9026 0 HDS 13 20...