26
English
5.906-432.0 Rev. 00 (06/15)
The feed of the liquid softener takes place in accordance
with the setting on the service switch. The setting is de-
scribed under 6.8 "Service switch". The feed only takes
place in the programme switch position "ECO" and "Warm
water" at a set water temperature
≥
50°C.
Bottle counter is increased by 1 after 2000 impulses.
The empty message takes place via the level sensor and
is shown via an indicator lamp or display.
The burner operation is also possible without liquid soften-
er. With hard water, however, malfunctions due to lime de-
posits must be expected.
Note
The dosing unit must not be switched off when using RM
111.
1 Lock
2 Washer
3 Liquid softener reservoir
1 Liquid softener reservoir
2 Level sensor
6.10 Liquid softener
6.10.1 Feed via tank (export variant)