– 4
For connection values refer to technical specifications.
Connect the supply hose (minimum length 7.5 m,
minimum diameter 3/4“) to the water connection of
the unit and to the water inlet (e.g. tap) using the
water connection adapter.
Note:
The supply hose is not included in the scope of
delivery.
If you want to suck in water from an external vessel, the
following modification is necessary:
Figure 6
Open fill opening for system care.
Release and remove the cover of the system care.
Remove water connection from the fine filter.
Unscrew the fine filter from the pump head.
Figure 7
Remove the system care reservoir.
Unscrew the top supply hose to the swimmer con-
tainer.
Figure 8
Connect the top supply hose at pump head.
Replug the rinse line of the detergent dosing valve.
Connect suction hose (minimum diameter 3/4“)
with filter (accessory) to the water connection point.
–
Max. suck height: 0.5 m
Until the pump sucked in water, you should:
Set the pressure/quantity regulation at the pump
unit to maximum quantity.
Close the dosing valve for the detergent.
DANGER
Risk of personal injury or damage! Never suck in water
from a drinking water container. Never suck in liquids
which contain solvents like lacquer thinner, petrol, oil or
unfiltered water. The sealings within the device are not
solvent resistant. The spray mist of solvents is highly in-
flammable, explosive and poisonous.
–
For connection values, see technical data and type
plate.
–
The electrical connections must be done by an
electrician according to IEC 60364-1.
DANGER
Risk of injury on account of electric shock!
–
Unsuitable electrical extension cables can be haz-
ardous. Only use electrical extension cables out-
doors which have been approved and labelled for
this purpose and have an adequate cable cross-
section.
–
Always unwind extension lines completely.
–
The plug and coupling of the extension cable used
must be watertight.
ATTENTION
The highest allowed net impedance at the electrical
connection point (refer to technical data) is not to be ex-
ceeded. In case of confusion regarding the power im-
pedance present on your connection, please contact
your utilities provider.
DANGER
Danger of explosion! Do not spray flammable liquids.
DANGER
Risk of injury! Never use the appliance without the spray
lance attached. Check and ensure proper fitting of the
spray lance prior to each use. The screw connection of
the spray lance must be finger-tight.
DANGER
Risk of injury! Hold the hand spray gun and the spray
pipe firmly with both hands.
DANGER
Risk of injury! The trigger and safety lever may not be
locked during the operation.
DANGER
Risk of injury! Contact Customer Service if the safety le-
ver is damaged.
ATTENTION
Risk of damage! Never operate device with an empty
fuel tank. The fuel pump will otherwise be destroyed.
To open the trigger gun: Actuate the safety lever
and trigger.
To close the hand spray gun: Release the safety le-
ver and trigger.
DANGER
Risk of injury! Switch the appliance off prior to replacing
nozzle and activate hand spray gun until device is pres-
sureless.
Secure the trigger gun. To do so, push the safety
catch towards the front.
Replacing the nozzle.
Set appliance switch to desired operating mode.
Indicator lamp for operational readiness lights up.
The device starts briefly and turns off, as soon as the
working pressure is reached.
Note:
If the indicator lamps for pump, rotation direction,
burner malfunction or engine are on during operation,
turn off the appliance immediately and repair malfunc-
tion, refer to "Help with malfunctions".
Release the trigger gun. To do so, push the safety
catch towards the back.
When activating the hand spray gun the device switch-
es back on.
Note:
If no water comes out of the high pressure nozzle,
vent pump. Refer to "Help with malfunctions - appliance
is not building up pressure".
Set temperature regulator to desired temperature.
30 °C to 98 °C
–
Clean with hot water.
100 °C to 150 °C
–
Clean using steam.
In steam operation (> 100°C), use the steam noz-
zle available as an accessory (see “Steam opera-
tion”).
Water connection
Suck in water from vessel
Power connection
Operation
Opening/closing the trigger gun
Replace the nozzle
Turning on the Appliance
Adjust cleaning temperature
22
EN
Summary of Contents for HDS 7/11-4 M
Page 2: ...2...
Page 3: ...1 5 12 14 10 6 9 8 4 3 2 1 23 24 25 26 27 22 21 17 18 19 20 7 11 13 16 15 3...
Page 4: ...28 29 MIN MAX MAX MIN 30 31 32 33 34 35 36 38 37 39 4...
Page 5: ...2 3 4 5 6 4 5 6 7 8 9 13 A B C 10 11 12 2 1 3 1 2 2 1 4 5 3 2 2 1 5...
Page 6: ...7 8 9 10 6 7 8 9 6...
Page 143: ...5 30 C 98 C 100 C 150 C 100 C MAX MIN 98 C 1 5 143 EL...
Page 145: ...7 9 5 10 o 0 OFF K rcher K rcher M8 5 mm 1 MAX 500 5 145 EL...
Page 147: ...9 0 MIN MAX 3 0 www kaercher com 147 EL...
Page 166: ...3 K RCHER K RCHER K RCHER Servopress 3 4 5 166 RU...
Page 168: ...5 IEC 60364 1 30 C 98 C 100 C 150 C 100 C MAX MIN 168 RU...
Page 170: ...7 0 OFF 0 C 1 9 5 10 0 OFF K rcher K rcher 170 RU...
Page 171: ...8 5 M8 1 MAX 10 0 OFF 0 OFF 0 OFF 500 5 2 3 4 HDS 7 11 HDS 7 12 1 2 3 4 1 2 171 RU...
Page 172: ...9 5 1 2 0 MIN MAX 3 0 3 4 1 HDS 12 18 HDS 13 20 2 HDS 12 18 HDS 13 20 172 RU...
Page 173: ...10 www kaercher com 173 RU...
Page 279: ...5 30 C 98 C 100 C 150 C 100 C MAX MIN 98 C 279 BG...
Page 281: ...7 1 9 5 10 0 OFF K rcher M8 5 1 T o 500 5 281 BG...
Page 283: ...9 0 3 0 www kaercher com 283 BG...
Page 326: ...3 K RCHER K RCHER K RCHER Servopress 3 4 5 326 UK...
Page 328: ...5 IEC 60364 1 30 C 98 C 100 C 150 C 100 C MAX MIN 98 C 328 UK...
Page 330: ...7 0 C 1 9 5 10 0 OFF Karcher Karcher 500 5 330 UK...
Page 331: ...8 5 M8 1 MAX 10 0 OFF 0 OFF 0 OFF 5 4 HDS 7 11 HDS 7 12 1 4 1 4 331 UK...
Page 332: ...9 1 2 0 MIN MAX 3 0 www kaercher com 1 HDS 12 18 HDS 13 20 2 HDS 12 18 HDS 13 20 332 UK...
Page 337: ......
Page 338: ......
Page 339: ......