background image

English

HDS 551 C, 558 C, 698 C, 798 C, 558 CSX, 698 CSX, 798 CSX

21

Mains connection

Refer to technical data and rating
plate for connected loads.

Fitting power plug

(only HDS 698../798..)
Have power plug fitted by
Kärcher AFTER-SALES
SERVICE or an authorised
electrician.

Set selector switch to "0"
Insert power plug

(only HDS 698../798..)

Whenever socket is changed,
check direction of rotation of
motor

If direction of rotation is correct,
powerful jet of air will be felt at
exhaust-gas opening of burner.
In the event of incorrect direction of
rotation, refer to Faults "Burner not
ignited"

If an extension cable is used, this
should always be fully uncoiled and
have an adequate cross-section.
(

1

0 m min. 

1

,5 mm

2

,

30 m min. 2,5 mm

2

)

OPERATION

*

 Never operate unit with fuel tank

empty! Fuel pump would
otherwise be destroyed!

Switching on unit

Fig. 3

Set selector switch (

1

) to "I"

Indicator lamp (4) lights
(not HDS 55

1

 C)

*

 If indicator lamp (2) or (3) comes

on during operation, switch off unit
immediately. Eliminate fault, refer
to Faults.

Unit starts up briefly and is switched
off as soon as operating pressure is
reached.

Illustration 8, Illustration 12

Release handgun
Actuation of handgun switches unit
back on again.

Bleed pump if no water emerges
from high-pressure nozzle. Refer to
Faults "No build-up of pressure by
unit"

Setting cleaning temperature

Set selector switch (

1

) to desired

temperature

30°C to 90°C
Hot water cleaning

1

00°C to 

1

50°C

Steam cleaning
(with steam nozzle 4.766-023)
(only HDS 558../698../798..)

Setting operating pressure and
flow rate

(only HDS 558../698../798..)

Fig. 9

Turning regulator clockwise:
Increases operating pressure (MAX)
Turning counter-clockwise: Reduces
operating pressure (MIN)

Servopress control

(not HDS 55

1

 C,

HDS 558 C 

1

.

1

70-

11

0,-

111

,

HDS 698 C 

1

.

1

73-

11

0,

HDS 798 C 

1

.

1

74-

11

0)

Set selector switch (

1

) to max. 98°C.

Set regulator to maximum operating
pressure.

Fig. 12

Operating pressure and flow rate
can be set at handgun.
Set pressure on unit if use is to be
made of reduced pressure for a
lengthy period. See Fig. 9

Measuring out the cleaning agent

*

  Use cleaning agents sparingly to

protect the environment

*

 The cleaning agent must be

suitable for the surface to be
cleaned.

Fig. 11

(only HDS 558../698../798..)
Set cleaning-agent concentration as
specified by manufacturer
0 =Working without cleaning agent

Metering setting

Concentration

1

0,25%

2

1

,00%

3

1

,25%

4

1

,50%

5

1

,75%

6

2,00%

Approximate values at maximum
operating pressure

(only HDS 55

1

 C)

Replace high pressure nozzle with
supplied low pressure nozzle or
switch over multiple nozzle to
"CHEM" position.

Fig. 16

Take out cleaning-agent inlet

Fig. 17

Turning strainer allows coarse
metering of cleaning agent.

Summary of Contents for HDS 551 C

Page 1: ...www karcher com 5 959 044 A2005729 04 03 HDS 551 C 558 C HDS 558 CSX 698 CSX 698 C 798 C 798 CSX 1 169 1 170 1 173 1 174...

Page 2: ......

Page 3: ......

Page 4: ...HDS 551 C 558 C 698 C 798 C 558 CSX 698 CSX 798 CSX 2 1 2 3 4 5 6 7 8 9 10 11 12...

Page 5: ...HDS 551 C 558 C 698 C 798 C 558 CSX 698 CSX 798 CSX 3 13 14 15 16 17 18 19 20 21 22 23...

Page 6: ...riftsvejledning 103 Reservedelsliste 277 Bruksveiledning 115 Reservedelsliste 277 Driftinstruktion 126 Reservdelslista 277 K ytt ohje 137 Varaosalista 277 zemeltet si utas t s 148 Cserealkatr szlista...

Page 7: ...water protection 24 Cleaning filter at cleaning agent suction hose 24 Changing oil 24 Faults 24 Warranty 25 General instructions 26 Technical data 27 Prior to initial startup operating manual and saf...

Page 8: ...l caster with parking brake 2 Crank handle for hose drum 3 Fuel tank inlet 4 High pressure hose 5 Cover latch 6 Handgun 7 Pressure gauge 8 Filler opening for cleaning agent and metering equipment 9 Wa...

Page 9: ...cleaning and treatment agents Your dealer will be pleased to advise you Fig 10 Fill with cleaning agent Mounting handgun Connect spray lance to handgun Insert high pressure nozzle in union nut Mount...

Page 10: ...from high pressure nozzle Refer to Faults No build up of pressure by unit Setting cleaning temperature Set selector switch 1 to desired temperature 30 C to 90 C Hot water cleaning 100 C to 150 C Stea...

Page 11: ...ressure always direct the high pressure stream onto the object to be cleaned from a sufficient distance away Recommended cleaning method Loosen up dirt Spray on cleaning agent sparingly and allow to r...

Page 12: ...torage is not possible DISCONTINUATION OF USAGE In the event of lengthy periods of non use or if frost free storage is not possible Drain off water and flush out equipment with antifreeze Drain cleani...

Page 13: ...ON indicator lamp off not HDS 551 C Motor overloaded overheated Set selector switch to 0 and allow motor to cool down for at least 5 min Have unit checked by After Sales Service if this does not remed...

Page 14: ...ning of burner Check direction of rotation If necessary have connection replaced by a qualified electrician No ignition spark Have unit checked by After Sales Service if no ignition spark is visible t...

Page 15: ...valve opens if the overflow valve or pressure switch is defective The safety valve is set at the factory and sealed Adjustment can only be made by After Sales Service Low water protection The low wate...

Page 16: ...g pressure cold hot water with standard nozzle supplied 13 MPa 130 bar 13 MPa 130 bar 12 MPa 120 bar 13 MPa 130 bar Flow rate steam Operating pressure steam with steam nozzle 4 766 023 Operating tempe...

Page 17: ...Operating pressure cold hot water with standard nozzle supplied 3 2 13 MPa 32 130 bar 3 2 9 MPa 32 90 bar 3 2 13 MPa 32 130 bar 3 2 12 MPa 32 120 bar 3 2 13 MPa 32 130 bar 3 2 9 MPa 32 90 bar Flow ra...

Page 18: ...lied 3 2 16 MPa 32 160 bar 3 2 17 MPa 32 170 bar Flow rate steam 300 l h 5 l min 360 l h 6 l min Operating pressure steam with steam nozzle 4 766 023 max 3 2 MPa 32 bar max 3 2 MPa 32 bar Operating te...

Page 19: ...HDS 551 C 558 C 698 C 798 C 558 CSX 698 CSX 798 CSX 277...

Page 20: ...HDS 551 C 558 C 698 C 798 C 558 CSX 698 CSX 798 CSX 278...

Page 21: ...HDS 551 C 558 C 698 C 798 C 558 CSX 698 CSX 798 CSX 279...

Page 22: ...HDS 551 C 558 C 698 C 798 C 558 CSX 698 CSX 798 CSX 280...

Page 23: ...HDS 551 C 558 C 698 C 798 C 558 CSX 698 CSX 798 CSX 281...

Page 24: ...orderungen der aktuellen EG Richtlinien und den angewandten Normen entsprechen Die Unterzeichnenden handeln im Auftrag und mit Vollmacht der Gesch ftsf hrung EU DECLARATION OF CONFORMITY We hereby dec...

Page 25: ...rmes appliqu es est garantie par des mesures internes Les soussign s agissent par ordre et avec les pleins pouvoirs de la Direction commerciale DICHIARAZIONE DI CONFORMIT CE Dichiariamo con la present...

Page 26: ...Por la presente declaramos los abajo firmantes que la m quina designada a continuaci n cumple tanto por su concepci n y clase de construcci n como por la ejecuci n que hemos puesto en circulaci n las...

Page 27: ...2001 Normas nacionais aplicadas TRD 801 TRD 301 DIN 2413 Processo de avalia o de conformidade aplicada Anexo V N vel de pot ncia de ru do medido HDS 551 C 91 dB A HDS 558 C 90 dB A HDS 698 C 91 dB A...

Page 28: ...e standarder der blev anvendt Underskriverne handler p forretningsledelsens vegne og med dennes fuldmagt EU KONFORMITETSERKL RING Vi erkl rer herved at maskinen som er beskrevet nedenfor i konstruksjo...

Page 29: ...EU direktiv och till mpade normer De undertecknade agerar p uppdrag av och med fullmakt av f retagsledningen EU VAATIMUSTENMUKAISUUSVAKUUTUS Me vakuutamme ett alla mainittu tuote vastaa suunnittelult...

Page 30: ...A A Szakmai sz vetkezetek f sz vets g nek a sepr sz v g pekre vonatkoz vizsg lati alapelvei Bels int zked sek ltal biztos tva van hogy a sorozatgy rt su k sz l kek mindig az aktu lis EG ir nyelveknek...

Page 31: ...jszym o wiadczamy e typ konstrukcyjny i koncepcja jak r wnie dostarczona przez nas wersja opisanej poni ej maszyny spe niaj odno ne podstawowe wymagania dotycz ce bezpiecze stwa pracy i ochrony zdrowi...

Page 32: ...Ma ini de m turare i aspirarePrin m suri interne se asigur ca aparatele produse n serie s corespund ntotdeauna directivelor actuale ale Comunit ii Europene i normelor aplicate Semnatarii ac ioneaz di...

Page 33: ...rnice ES Stroj rensk smernice ES 98 37 EG Smernice n zkeho nap tia ES 73 23 EWG zmenen na z klade 93 68 EWG Smernice ES Elektromagnetick kompatibilita 89 336 EWG zmenen na z klade 91 263 EWG 92 31 EWG...

Page 34: ...aju zahtjevima aktuelnih EU smjernica i sprovedenih normi Potpisnici djeluju u ime i s punomo ju rukovodstva EU IZJAVA O SKLADU SA PRAVILNICIMA Ovim izjavljujemo da je ma ina navedena u nastavku na os...

Page 35: ...B A HDS 798 C 92 dB A HDS 551 C 93 dB A HDS 558 C 92 dB A HDS 698 C 92 dB A HDS 798 C 93 dB A 5 957 576 09 02 Alfred K rcher Kommanditgesellschaft Sitz Winnenden Registergericht Waiblingen HRA 169 Per...

Reviews: