Basic Settings and Service Procedures
HDS Middle Range / HDS Premium Range
Page 64 / 127
Service Manual 04.2008
3.1.1 Adjusting the stopping behaviour
Function
30 °C
LED display
Meaning
ON30MIN
Behaviour of the unit
after 30 minutes’
continuous operation.
Setting is saved.
Unit switches off after 30 minutes’
continuous operation.
Unit does not switch off after 30
minutes’ continuous operation
(manufacture settings).
Unit switches off after 30 minutes’
standby operation.
35 °C
OFF30MIN
Behaviour of the unit
after 30 minutes’
continuous standby
operation.
Setting is saved.
Unit does not switch off after 30
minutes’ standby operation
(manufacture settings).
3.1.2 Adjusting the leakage behaviour
Function
40 °C
LED display
Meaning
LECKAGEONOFF
Behaviour of the unit
after 10 short pump start-
ups (pump running time
less than 2 seconds).
Setting is saved.
Unit switches off after 10 short
pump start-ups (manufacture
settings).
Unit does not switch off after 10
short pump start-ups.