F. Troubleshooting
F2
Problem
Possible cause
Remedy
By whom
Strong odour nuisance
Disinfectant metering tank
(6) empty
Metered quantity in (6) too
low
Metering solenoid valve
defective
Disinfectant no longer active
Refill tank
Increase metered quantity
Replace solenoid valve
Check disinfectant and if necessary replace
with new disinfectant
Operator
Customer
Service
Customer
Service
Operator/
Customer
Service
Very high consumption of
degerminating
Degerminating agent
metering (6) set too high
Defective solenoid valve
Reduce dosage
Replace solenoid valve
Customer
Service
Industrial water storage
tank (9) overflows
Level sensor in the storage
tank (9) soiled or defective
Solenoid valve for fresh
water inlet (11) soiled or
defective
Clean or replace
Clean or replace
Operator/
Customer
Service
Reaction tank (3) is not
fully drained
Storage tank for industrial
water (9) full
Level sensor im storage tank
(9) soiled or defective
Hose or pumps (16 or 17)
between the reaction tank
(3) and filter unit blocked
Dirty agitator shaft or
problem with contacts
Agitator shaft has become
detached from motor shaft
In recycling mode wait for the water to be
consumed, otherwise clean or replace the
supply pump for the high-pressure cleaner
(12)
Clean or replace
Clean or replace
Clean or replace
Re-attach shaft and tighten coupling securely
Operator/
Customer
Service
Operator/
Customer
Service
Operator/
Customer
Service
Operator/
Customer
Service
Customer
Service
Stirrer motor and drainage
pumps (16, 17) do not
switch off after draining the
reaction tank
Dirty agitator shaft or
problem with contacts
Clean or replace
Operator/
Customer
Service
Cleavage powder is not
pumped into the reaction
tank
Metering aperture (f) or
metering device blocked up
with moist splitting agent
No voltage supply to metering
motor, or motor is defective
Empty splitting agent out of metering unit (5)
Clean out aperture or metering device
Add dry splitting agent
Check supply voltage or replace motor, if
required
Operator
Customer
Service
Motor for metering splitting
agent is running although
there is no splitting agent left
Dirty or defective level
sensor
Clean or replace level sensor
Operator/
Customer
Service
Stirrer shaft in the reaction
tank (3) doesn’t rotate
No voltage supplied to agitator
motor, or motor is defective
Agitator shaft has become
detached from motor shaft
Check supply voltage or replace motor, if
necessary
Re-attach shaft and tighten coupling securely
Customer
Service