![Kärcher HD 7/16-4 ST Instructions Manual Download Page 19](http://html1.mh-extra.com/html/karcher/hd-7-16-4-st/hd-7-16-4-st_instructions-manual_4145305019.webp)
-
2
In case of leaks in the high pressure sys-
tem, the appliance is shut off.
After the operation readiness period, a so-
lenoid valve opens in the high pressure
system and relieves the pressure.
The lack of water fuse in the float container
prevents the high pressure pump from run-
ning dry in case of a lack of water.
–
This equipment produces water under
high pressure downstream to high pres-
sure cleaning devices. If required the
detergent is drawn in and added to the
water.
–
The high pressure module is perma-
nently installed in a dry, frost-free room.
The temperature at the installation site
should not exceed 40 °C. The high
pressure water is distributed through a
fixed network of pipes.
Alternatively, a hand spray gun with a
high pressure hose can be connected
directly to the high pressure outlet of the
appliance.
–
The high pressure model must be in-
stalled at a wall in such a way that the
rear opening is sealed by the wall.
Danger
Risk of injury! Follow the respective safety
regulations when operating at gas stations
or other dangerous areas.
Note
Only clean water may be used as high
pressure medium. Impurities will lead to in-
creased wear and tear or formation of de-
posits.
* Test volume 1litre, Settling time 30 min-
utes
** decalcification measures are necessary
if the values are higher
Leakage monitoring
Pressure relief (option)
Lack of water fuse (option)
Proper use
Please do not let mineral oil contaminat-
ed waste water reach soil, water or the
sewage system. Perform engine cleaning
and bottom cleaning therefore only on
specified places with an oil trap.
Water quality requirements
pH value
6,5...9,5
electrical conductivity
< 2000
μ
S/cm
removable materials
< 0.5 mg/l *
filterable materials
(grain size below 0.025
mm)
< 20 mg/l
Hydrocarbons
< 20 mg/l
Chloride
< 300 mg/l
Calcium
< 85 mg/l **
Total hardness
< 15 °dH **
Iron
< 0.5 mg/l
Manganese
< 0.05 mg/l
Copper
< 0.02 mg/l
free of bad odours
19