background image

6

English

 4. Operating the cleaner

Protection from sub-zero temperatures

Caution! Water which has frozen in the cleaner
can destroy parts of it. At best store the cleaner
in a heated room during the winter or empty it
or rinse it thoroughly with antifreeze.

• Empty the cleaner

– Unscrew supply hose and high-pressure hose

from the cleaner.

– Leave the cleaner running until the pump and

lines have emptied (max. 1 minute).

• Putting in antifreeze

For longer intervals between operations,
pumping antifreeze through the cleaner is to be
recommended. By this means also you obtain
a sure protection against corrosion.

5. Care and maintenance

• Check cleaner (pump) for any leaks. Three

drops per minute are allowable and can appear
on the underside of the cleaner. Seek the help
of Customer Service if leaks are more serious.

Every week

• Check oil level in oil reservoir (16): if the oil is

milky (water in oil), seek the help of Customer
Service immediately.

• Clean the strainer at the water outlet.
• Clean the filter at the suction hose for

detergent.

Annually or after 500 operating hours

• Change the oil

– For oil quantity and type see Technical

Specifications.

– Undo fastening screws (12), remove unit

cover, remove cover of oil reservoir.

– Lay cleaner on its side and drain oil into

a suitable container.

– Fill slowly with fresh oil; air bubbles have

to escape.

Danger!  Before undertaking any care or
maintenance work on the cleaner, pull out the
power plug.
Caution! When changing the oil, dispose of any
waste oil only at authorised collection points.

Safety inspection/maintenance
contract

You can arrange with your dealer to have
a regular safety inspection carried out or to have
a maintenance contract. Please seek advice on
this.

Each time before operating the
cleaner

• Check connecting cable for damage (risk of

getting an electric shock), have a damaged
connecting cable replaced without delay by
authorised Customer Service personnel or an
electrician.

• Check high-pressure hose for damage

(danger of explosion), replace a damaged high-
pressure hose without delay.

Summary of Contents for HD 650

Page 1: ...5 959 143 A2002644 11 01 HD 650 HD 651 USA CDN...

Page 2: ......

Page 3: ...becomes operative when your dealer has completed the reply card accompanying the sale of the unit has stamped and signed it and you have then sent the reply card to the marketing company in your count...

Page 4: ...Electrical connection Caution The voltage specified on the model rating plate must correspond to the voltage supplied Caution Use an extension cable whose cable cross section is adequate see Technica...

Page 5: ...of consideration for the environment K rcher cleaning agents guarantee trouble free operation Please seek advice or ask for our catalogue of information sheets on cleaning agents Active cleaner RM 31...

Page 6: ...Service immediately Clean the strainer at the water outlet Clean the filter at the suction hose for detergent Annually or after 500 operating hours Change the oil For oil quantity and type see Technic...

Page 7: ...ns Check all supply lines to the pump for leaks or obstructions Seek the help of Customer Service if necessary Pump is leaky Three drops per minute are allowable and can appear on the underside of the...

Page 8: ...hose length m 7 5 7 5 Supply hose minimum diameter inches 1 2 1 2 Suction height from an open container 20 C m 0 5 0 5 Supply pressure max psi 140 140 Performance data kpa psi OTE TWM Operating pressu...

Page 9: ...5 044 082 0 6 414 252 0 5 731 040 0 4 580 337 0 2 880 296 0 4 760 356 0 2 880 296 0 6 390 057 0 2 880 296 0 6 390 057 0 4 775 352 0 6 435 197 0 MAX MIN O I 6 304 099 0 1 150 110 CSA CDN 1 150 111 USA...