 6. Troubleshooting

Danger!  Before any repair work is undertaken, switch the cleaner off and pull out the power plug.
Have electrical components checked and repaired only be authorised Customer Service personnel.
For faults which are not identified in this chapter, or when in doubt or when expressly instructed to
do so, consult authorised Customer Service personnel.

Cleaner does not work

• Check mains voltage.
• Check connecting cable for damage.
• If the motor has overheated, let the cleaner

cool down. Then switch it on again.

• Consult Customer Service if there is an

electrical fault.

Cleaner does not come up to pressure

• Set nozzle (22) to “high pressure”.
• Clean nozzle or replace with new one.
• Clean strainer at the water connection (15).
• Evacuate air from the cleaner.
• Check water inlet volume (see Technical

Specifications).

• Check all supply lines to the pump for leaks or

obstructions.

• Seek the help of Customer Service if

necessary.

Pump is leaky

• Three drops per minute are allowable and can

appear on the underside of the cleaner. Seek
the help of Customer Service if leaks are more
serious.

Pump makes a knocking noise

• Check all supply lines as well as the detergent

system for leaks.

• Evacuate air from the cleaner.
• Seek the help of Customer Service if

necessary.

Detergent is not being drawn in

• Set nozzle (22) to “low pressure”.
• Check detergent suction hose (11) with filter for

leaks or obstructions and clean it if necessary.

• Clean/renew non-return valve in detergent

suction-hose (11) connection.

• Open detergent metering valve (8) or

check it for leaks/remove obstruction. Also
clean venting orifice in the cap.

• Tip the cleaner backwards over the wheels.

Empty the detergent reservoir (10) and rinse it
out.

• Seek the help of Customer Service if

necessary.

7. Spare parts

You will find a list of spare parts at the end of
these operating instructions.

Summary of Contents for HD 650

Page 1: ...5 959 143 A2002644 11 01 HD 650 HD 651 USA CDN...

Page 2: ......

Page 3: ...becomes operative when your dealer has completed the reply card accompanying the sale of the unit has stamped and signed it and you have then sent the reply card to the marketing company in your count...

Page 4: ...Electrical connection Caution The voltage specified on the model rating plate must correspond to the voltage supplied Caution Use an extension cable whose cable cross section is adequate see Technica...

Page 5: ...of consideration for the environment K rcher cleaning agents guarantee trouble free operation Please seek advice or ask for our catalogue of information sheets on cleaning agents Active cleaner RM 31...

Page 6: ...Service immediately Clean the strainer at the water outlet Clean the filter at the suction hose for detergent Annually or after 500 operating hours Change the oil For oil quantity and type see Technic...

Page 7: ...ns Check all supply lines to the pump for leaks or obstructions Seek the help of Customer Service if necessary Pump is leaky Three drops per minute are allowable and can appear on the underside of the...

Page 8: ...hose length m 7 5 7 5 Supply hose minimum diameter inches 1 2 1 2 Suction height from an open container 20 C m 0 5 0 5 Supply pressure max psi 140 140 Performance data kpa psi OTE TWM Operating pressu...

Page 9: ...5 044 082 0 6 414 252 0 5 731 040 0 4 580 337 0 2 880 296 0 4 760 356 0 2 880 296 0 6 390 057 0 2 880 296 0 6 390 057 0 4 775 352 0 6 435 197 0 MAX MIN O I 6 304 099 0 1 150 110 CSA CDN 1 150 111 USA...

Page 10: ......

Reviews: