background image

– 6

The appliance should always be con-
nected to the electrical mains using a 
plug. It is forbidden to permanently con-
nect the appliance to the power supply. 
The plug is only for mains separation.
Check the power cord with mains plug 
for damage before every use. If the 
power cord is damaged, please ar-
range immediately for the exchange by 
an authorized customer service or a 
skilled electrician.
The plug and coupling of the extension 
cable used must be watertight.
Use the extension cord that has an ad-
equate cross-section (see "Technical 
Data") and unwind it fully from the ca-
ble drum.
Unsuitable extension cables can be 
hazardous. Only use extension cables 
outdoors which have been approved 
for this purpose and labelled with a suf-
ficient cable cross section:

For connection values, see type plate/
technical data.

Warning

Observe regulations of water supplier. 
According to the applicable 
regulations, the appliance 
must never be used on the 
drinking water supply without a system 
separator. Use a suitable system sep-
arator manufactured by KÄRCHER; or, 
as an alternative, a system separator 
as per EN 12729 Type BA. Water flow-
ing through a system separator is con-
sidered non-drinkable. 

Caution
Always connect the system separator 
to the water supply, never directly to 
the appliance!

For connection values refer to techni-
cal specifications

Connect the supply hose (minimum 
length 7.5 m, minimum diameter 3/
4“) to the water connection point of 
the machine and at the water sup-
ply point (for e.g. a tap). 

Note
The supply hose is not included.

Open the water supply.

Screw the suction hose with filter 
(order no. 4.440-238.0) to the water 
connection.

Deaerate the appliance:
Unscrew the nozzle. 
Switch on the appliance and let it run 
until the water exiting is bubble-free. 
At the end let the appliance run for 
approx. 10 seconds - then switch 
off. Repeat the procedure for a cou-
ple of times.

Switch off the appliance and fit the 
nozzle again. 

Danger

Risk of explosion!
Do not spray flammable liquids.
If the appliance is used in hazardous 
areas (e.g. filling stations) all of the 
safety provisions and operating in-
structions detailed in this manual must 
be observed.

Caution
Clean engines only at places with cor-
responding oil separators (environ-
mental safety).

Note
The appliance is equipped with a pres-
sure switch. The motor starts up only 
when the lever of the pistol is pulled.

Set the appliance switch to "I".

Water connection

Connection to the water supply

Drawing in water from open reservoirs

Operation

High pressure operation

8

EN

Summary of Contents for HD 4.5/32-4S Eb

Page 1: ...R egister and w in w w w kaercher com HD 4 5 32 4S Eb HD 4 5 32 4S Ec 59658610 04 13...

Page 2: ...2...

Page 3: ...lock trigger in the ON position 12 Keep operating area clear of all per sons 13 Follow the maintenance instruc tions specified in the manual 14 Risk of Injection or Injury Do Not Di rect Discharge Str...

Page 4: ...ction hazard equipment can cause serious injury if the spray penetrates the skin Do not point the gun at anyone or any part of the body In case of penetra tion seek medical aid immediately This system...

Page 5: ...ng gun 2 Lever for hand spray gun 3 High pressure hose 4 Storage for hand spray gun 5 Dosage valve for detergent 6 Detergent tank lid 7 Detergent Tank 8 Detergent suction hose with deter gent filter a...

Page 6: ...azardous situation that could lead to mild injury to persons or damage to property High pressure jets can be dangerous if improperly used The jet may not be di rected at persons animals live electri c...

Page 7: ...d volume reg ulation Lock in the cable hook in the side hole on the handle Fasten the high pressure hose to the high pressure connection Danger Danger of injury by electric shock The appliance may onl...

Page 8: ...con sidered non drinkable Caution Always connect the system separator to the water supply never directly to the appliance For connection values refer to techni cal specifications Connect the supply h...

Page 9: ...ill detergent tank Set nozzle to CHEM Set dosing value for detergent to the desired concentration Spray the detergent sparingly on the dry surface and allow it to react but not to dry Spray off loosen...

Page 10: ...ained device Store the appliance in a frost free area Emptying the detergent tank see Care and Maintenance as re quired Drain water Pump in conventional frost protec tion agents through the appliance...

Page 11: ...liance Call Custom er Service if there is heavy leakage Check oil level Please contact Cus tomer Service immediately if the oil is milky water in oil Clean the fine filter Unpressurize the appliance U...

Page 12: ...tions and hand spray gun for leaks blinks red twice Engine is too hot Set the appliance switch to 0 Allow device to cool down Set the appliance switch to I blinks red thrice Fault in the voltage suppl...

Page 13: ...spare parts ensures that the appliance can be operated safely and trouble free At the end of the operating instruc tions you will find a selected list of spare parts that are often required For additi...

Page 14: ...a Working pressure PSI 435 3200 Max operating over pressure PSI 3600 Nozzle size 055 Flow rate gpm 2 2 4 5 Detergent suck in gpm 0 0 3 Max recoil force of hand spray gun N 62 Values determined as per...

Page 15: ......

Page 16: ...http www kaercher com dealersearch...

Reviews: