24
Troubleshooting and basic settings
Unit switches on and off continuously
Detergent non-return valve leaking
– Remove detergent non-return valve. If neces-
sary replace defective parts. Do not grease
steel ball and O-ring before installing.
Overflow valve disassembled
Overflow valve leaking
– Disassemble overflow valve completely and
check all O-rings/support rings. Replace de-
fective parts if necessary.
– Lubricate all O-rings with silicone grease
6.288-080.
– Adjustment, see page 22.
Detergent non-return valve
Adjust pressure switch
Setting pressure switch
– Unit switches on and off continuously when
operated with the original accessories. Reset
(see page 22).