English

Operating Instructions HD 10/25 S/SX Plus, 13/18 S/SX Plus

17

Switching on the unit

Electrical connection

Caution!
The voltage specified on the model rat-

ing plate must correspond to the voltage sup-
plied.

Caution!
The maximum tolerable mains 

impedance at the electrical contact point (see 
Technical Data) must not be exceeded.

Caution!
Use an extension cable with a sufficient 

cable cross-section (see Technical Specifica-
tions) and unwind it fully from the cable drum.

For connected loads see model rating plate/
Technical Specifications.

Caution!
It is essential that the unit is connected 

to the power supply by means of a plug. An in-
separable connection to the power supply is 
prohibited. The plug is used to disconnect 
from the mains.

Water connection/Suction feed 
operation

Connection to water main

Caution!
Pay attention to the regulations of the 

water supply company; according to DIN 
1988, the unit may not be connected direct to 
the public drinking water supply. A short-term 
connection via a non-return valve 
(Order no. 6.412-578) is allowed.

For connected loads see Technical Specifica-
tions.

„

Connect a supply hose (not supplied) to the 
water outlet on the unit and to the water in-
let (e.g. water tap).

„

Open water inlet.

Suctioning water from an open container

„

Screw suction hose with filter 
(Order no. 4.440-238) to the water outlet.

„

Vent the unit before using.

„

To evacuate air from the unit, unscrew the 
nozzle and leave the unit running until wa-
ter exits with no air bubbles.

„

Switch off the unit and screw the nozzle 
back on.

Operating the unit

Danger!
Observe the relative safety regulations 

when using the unit at filling stations or other 
high-risk areas.

Caution!
Only clean engines in places which 

have appropriate oil separators (protection of 
the environment).

Caution!
Only wash animals with the low-

pressure fan jet (see "Selecting the type of 
spray").

Operating with high pressure

The unit is equipped with a pressure switch. 
The motor only starts up when the lever is re-
tracted.

„

Unwind the high-pressure hose fully from 
the cable drum.

„

Set the unit switch to "I". The indicator light 
will go green.

„

Unlock the hand-held spray gun and retract 
the lever of the gun.

„

Adjust operating pressure and flow rate 
(+/–) by rotating the pressure/flow control 
(infinitely variable). 

„

At the lowest flow rate the waste heat from 
the motor will heat the water to approx. 
15 °C.

!

Summary of Contents for HD 10/25 S Plus

Page 1: ...www karcher com HD 10 25 S HD 10 25 S Plus HD 10 25 SX Plus HD 13 18 S Plus HD 13 18 SX Plus 5 959 675 A 2006919 10 03 ...

Page 2: ...2 Deutsch English Français Italiano Español Svenska Polski Pºcc å 6 15 24 33 42 51 60 69 ...

Page 3: ......

Page 4: ...4 HD 10 25 S HD 10 25 S Plus HD 13 18 S Plus ...

Page 5: ...5 HD 10 25 SX Plus HD 13 18 SX Plus ...

Page 6: ...ou use the cleaner for the first time read these operating instructions and take special note of the accompanying booklet Safety Instructions for High Pressure Clean ers No 5 951 949 Use of the cleaner Use this unit exclusively for cleaning with high pressure jet and deter gent e g cleaning of machines vehicles buildings tools cleaning with high pressure jet without de tergent e g cleaning facades...

Page 7: ...held spray gun with pressure and flow control For appliances with hose reel Insert the crank handle into the hose drum shaft Connect the high pressure hose to the handgun For appliances without hose reel Lock cable clincher into bore lateral to the handle For handguns with threaded connection Tighten the high pressure hose according ly For handguns without threaded connection Lever off retaining c...

Page 8: ...Technical Specifica tions Connect a supply hose not supplied to the water outlet on the unit and to the water in let e g water tap Open water inlet Suctioning water from an open container Screw suction hose with filter Order no 4 440 238 to the water outlet Vent the unit before using To evacuate air from the unit unscrew the nozzle and leave the unit running until wa ter exits with no air bubbles ...

Page 9: ...cleaned Use only detergents which are released by Kärcher Proportions of detergent to be used and accompanying instructions should be not ed carefully Use detergents sparingly out of consideration for the environment Kärcher cleaning agents guarantee trouble free operation Please seek advice or ask for our catalogue of information sheets on clean ing agents Fill detergent reservoir Set nozzle to S...

Page 10: ...ansporting the cleaner To transport the cleaner over relatively long stretches take hold of it by the handle and pull it along behind you Empty the detergent reservoir before trans porting it horizontally Storing the cleaner Place the handgun in the support Reel in the high pressure hose and hang it over the hose rest or Wind the high pressure hose on to the hose reel Push in the crank handle to l...

Page 11: ...ty and type see Technical Specifications Undo the fastening screw remove the hood unscrew the front oil drain plug on the motor housing Drain oil into a suitable container Screw in the oil drain plug Fill slowly with fresh oil air bubbles have to escape As and when required Emptying and cleaning the detergent tank Pull out the screw cap and hose for the detergent tank Place the unit on its rear Em...

Page 12: ...er replace if required Evacuate air from the cleaner see Switch ing on the unit Check water inlet volume see Technical Specifications Check all supply lines to the pump for leaks or obstructions Seek the help of Customer Service if nec essary Pump is leaky Three drops per minute are allowable and can appear on the underside of the unit Seek the help of Customer Service if leaks are more serious Pu...

Page 13: ... design and construction as well as in the version marketed by us This declaration will cease to be valid if any modifications are made to the machine without our express approval Product High pressure cleaner Type 1 286 xxx 1 292 xxx Relevant EU Directives EU Machinery Directive 98 37 CE EU Low Voltage Equipment Directive 73 23 EEC amended by 93 68 EEC EU Directive on Electromagnetic Compatibilit...

Page 14: ...diameter inches 3 4 3 4 Suction height from an open container 20 Cm 0 5 0 5 Supply pressure max MPa bar 1 10 1 10 Performance data Operating pressure MPa bar 3 25 30 250 3 18 30 180 Max operating overpressure safety valve MPa bar 27 5 275 19 8 198 Flow rate l h l min 500 1 000 8 3 16 7 650 1 300 8 3 21 7 Detergent intake l h l min 0 80 0 1 3 0 80 0 1 3 Recoil force of the handgun N 62 68 Sound emi...

Page 15: ......

Page 16: ......

Reviews: