background image

     

3

Note

Do not use highly foaming detergents. Ob-
serve the dosing notes.

Recommended detergents:

Î

Open the cover of the fresh water reser-
voir.

Î

Pour in water/detergent mixture. Maxi-
mum temperature of the liquid 50°C

Note

The fresh water reservoir cover can be 
used to meter the detergent. The capacity 
of the cover up to the mark represents 1% 
of the fresh water reservoir capacity.

Î

Close the cover of the fresh water res-
ervoir.

Î

Place the slider vertically.

Î

Position the rotary handle for the brush 
contact pressure in the drive position.

Î

Use the pushing handle to push the ap-
pliance to the place of use.

Î

Place the slider vertically and tilt the 
lock up.

Î

Install the transport wheels.

-

Caution

Danger of damage due to leaking water. 
Remove the waste water and fresh water 
reservoirs before tilting the appliance.

Î

Remove the filled waste and fresh wa-
ter reservoirs from the appliance and 
transport them separately.

Î

Tilt the appliance to the side and drive it 
to the place of use on its transport 
wheels.

If the transport wheels hinder the use of the 
appliance:

Î

Press the transport wheel release but-
ton and pull the transport wheel out.

Î

Insert the transport wheels into their 
holder until they stop.

Î

Place the slider vertically.

Î

Pull out the rotary handle of the brush 
contact pressure and set it to the de-
sired value.

Note

Carry out the initial cleaning attempts with 
less contact pressure. Increase contact 
pressure step-by-step until the desired 
cleaning result is achieved. A correct set-
ting of the contact pressure reduces the 
wear and tear of the brushes.
The brush drive is switched off when there 
is overload. 
When cleaning with microfibre rollers, the 
contact pressure must not be adjusted 
higher than the position mentioned below. 
With a higher contact pressure, there is a 
danger of destroying the microfibre rollers.

1 Brush contact pressure
2

Driving

3 Note: Pull out the rotary handle for the 

brush contact pressure prior to this ad-
justment.

Danger

Risk of electric shock. Check the mains ca-
bles of the machine each time before using 
the machine to see that it is not damaged. 
Never operate a machine with damaged 
cables. Get the damaged cables replaced  
by an electrician.

Caution

Risk of damage. The maximum permitted 
net impedance at the electrical connection 
point (refer to technical data) is not to be 
exceeded.
Use the extension cord that has an ade-
quate cross-section (see "Technical Data") 
and unwind it fully from the cable drum.

Î

Insert the looped end of the extension 
cable in the strain relief hook.

Î

Plug in the mains plug.

Danger

Risk of injury on account of electric shock 
caused by a damaged mains cable. Do not 
let the mains cable come in contact with the 
rotating brushes or pads.

Î

If the detergent solution is to be vacu-
umed off after the cleaning process: 
Check that all vacuum bars are inserted 
into the appliance
Press the pedal to lower the vacuum 
bar.

Î

Place the slider vertically.

Î

Turn on the brush irrigation by using the 
switch for the detergent solution.

Î

Turn on the brushes by using the switch 
for the brush drive.

Î

Swivel the slider toward the operator - 
the chassis is retracted and the brushes 
touch the floor.

Î

Move the appliance over the surface to 
be processed by the slider.

Caution

Risk of damage to the floor covering. Do 
not operate the appliance on the spot.

Î

Remove both vacuum bars from the ap-
pliance (see chapter "Maintenance 
tasks/replacing vacuum bar").

Î

Place the slider vertically.

Î

Turn on the brushes by using the switch 
for the brush drive.

Î

Swivel the slider toward the operator - 
the chassis is retracted and the brushes 
touch the floor.

Î

Move the appliance over the surface to 
be processed by the slider.

Caution

Risk of damage to the floor covering. Do 
not operate the appliance on the spot.

Note

To polish furniture, the fresh water and 
wastewater reservoirs can be removed.

Î

Release the switch for detergent solution.

Î

Push the appliance forward for another 
1-2 m to draw off residual water.

Î

Release the brush drive button.

Î

Press the pedal to lower the vacuum bar.

Î

Place the slider vertically - the brushes 
are elevated.

Î

Disconnect the mains plug.

Caution

Danger of deforming the brushes. When 
switching off the appliance, take the load off 
the appliance by placing the slider vertically.

Î

Open the locks for the fresh water res-
ervoir.

Î

Tilt the carrying hanlde for the wastewa-
ter reservoir towards the side.

Î

Lift up the fresh water reservoir and car-
ry it to the disposal site.

Warning

Please observe the local provisions regard-
ing the wastewater treatment.

Î

Remove the cover of the fresh water 
reservoir and pour out the liquid via the 
notch.

Application

Detergent

Routine cleaning of all water 
resistant floors

RM 780
RM 746

Routine cleaning of glossy 
surfaces (e.g. granite)

RM 755 es

Routine cleaning and basic 
cleaning of industrial floors

RM 69 ASF

Routine cleaning and basic 
cleaning of fine stoneware tiles

RM 753

Routine cleaning of tiles in 
sanitary areas

RM 751

Cleaning and disinfection in 
sanitary areas

RM 732

Removal of coating from all al-
kali-resistant floors (e.g. PVC)

RM 752

Removal of coating from lino-
leum floors

RM 754

Driving to the Place of Use

Short distances on even surfaces

Longer distances on uneven surfaces

Adjust the brush contact pressure

Establish  mains contact

Cleaning

Polishing

Shutting Down the Appliance

Emptying the Fresh Water Reser-

voir

11

EN

Summary of Contents for BR 40/10 C Adv

Page 1: ...3 Deutsch 3 English 9 Français 15 Italiano 21 Nederlands 27 Español 33 Português 39 Dansk 45 Norsk 51 Svenska 57 Suomi 63 Ελληνικά 69 Türkçe 76 Русский 82 Magyar 89 Čeština 95 Slovenščina 101 Polski 107 Româneşte 113 Deutsch 3 English 9 Français 15 Italiano 21 Nederlands 27 Español 33 Português 39 Dansk 45 Norsk 51 Svenska 57 Suomi 63 Ελληνικά 69 Türkçe 76 Русский 82 Magyar 89 Čeština 95 Slovenšči...

Page 2: ...s factories shops offices and rental companies The appliance may only be used for the cleaning of hard surfaces that are not sensitive to moisture and polishing op erations The application temperature ranges from 5 C to 40 C The appliance is not suited for the cleaning of frozen grounds e g in cold stores The appliance may only be equipped with original accessories and spare parts The appliance ha...

Page 3: ...ts Î Connect the slider halves to the lock screws discs and star grips Î Fasten the cable to the slider using clips With the BR 40 10 C Classic the transport wheels are not included in the delivery An attachment kit with transport wheels is list ed in the chapter Accessories Î Insert the transport wheel axles into the borings on the appliance and lock them The brushes must be installed before the ...

Page 4: ...account of electric shock caused by a damaged mains cable Do not let the mains cable come in contact with the rotating brushes or pads Î If the detergent solution is to be vacu umed off after the cleaning process Check that all vacuum bars are inserted into the appliance Press the pedal to lower the vacuum bar Î Place the slider vertically Î Turn on the brush irrigation by using the switch for the...

Page 5: ... for wear and replace the vacuum bar if required Î Check the brushes for wear replace if required Î Clean the water distribution bars above the brushes Î Check the condition of the seals be tween the appliance and the wastewa ter reservoir replace if required Î Clean the brush tunnel Î Have the prescribed inspection carried out by the customer service Î Lift the vacuum bar by activating the pedal ...

Page 6: ...ck if foreign matters block the brushes remove foreign matter if required Reduce contact pressure Overcurrent protective switch was triggered The overcurrent protective switch will allow the op eration after max one minute Appliance vibrates Brush rollers are deformed because they were not unloaded by tilting the slider vertically when parking the appliance replace brush rollers Specifications 1 7...

Page 7: ...arts that are often required For additional information about spare parts please go to the Service section at www kaercher com Accessories Order No Piece Machine requires piece Brush roller red medium standard For cleaning slightly dirtied or sensitive floors 4 762 249 0 1 2 Brush roller green grit For cleaning heavily dirtied floors 4 762 252 0 1 2 Brush roller orange high low For scrubbing struc...

Page 8: ...167 ...

Page 9: ...her S p A Via A Vespucci 19 21013 Gallarate VA 39 848 998877 www karcher it IE Kärcher Limited Ireland 12 Willow Business Park Nangor Road Dublin 12 01 409 7777 www kaercher ie JP Kärcher Japan Co Ltd Irene Kärcher Building No 2 Matsusaka Daira 3 chome Taiwa cho Kurokawa gun Miyagi 981 3408 81 22 344 3140 www karcher co jp KR Karcher Co Ltd South Korea 2nd Floor Youngjae Building 50 1 51 1 Sansoo ...