20
English
9.808-230.0 Rev. 01 (03/20)
1 Water quantity regulator
2 Square
3 Water dosing valve
4 Water channel
A View from above
The inflow of the water volume is adjusted via the regulat-
ing knob water value.
The square connects the regulating knob water volume
with the water dosing valve.
Depending on the position of the regulating knob water vol-
ume, the water dosing valve is opened or closed.
The set water volume flows through the water channel to
the outlet onto the disc brush.
When the regulating knob water volume is completely
opened, the supplied water volume varies between 2.2 l/
min with a full and 0.9 l/min with an almost empty fresh wa-
ter tank.
Upon ending the work, the water dosing valve must be
closed.
Note
Unless otherwise described, the installation takes place in
reverse order.
Remove the waste water tank.
1 waste water tank
2 Hose clip
3 Dirt water drain hose
Loosen the hose clip.
Remove waste water drain hose.
Installation information
Secure the hose clip in a way that it does not touch the
fresh water tank.
030 Function
040 Service activities
ADSA Uninstall / install waste water drain hose
Summary of Contents for BD 50/50 C Bp Classic
Page 72: ...72 English 9 808 230 0 Rev 01 03 20 Note Ep variant Cable harness...
Page 74: ...74 English 9 808 230 0 Rev 01 03 20 Mains distribution 9 763 119 0 Suction turbine 9 763 120 0...
Page 75: ...English 9 808 230 0 Rev 01 03 20 75 Indicator light voltage supply 9 763 122 0...
Page 150: ...Espa ol 9 808 230 0 Rev 01 03 20 150 Nota Variante Ep arn s de cables...
Page 153: ...153 Espa ol 9 808 230 0 Rev 01 03 20 Alimentaci n de tensi n del piloto de control 9 763 122 0...
Page 226: ...Fran ais 9 808 230 0 Rev 01 03 20 226 Remarque Variante Ep Faisceau de c bles...