Microwave barrier
- 26 -
network address.
Programming the transmitter
To program the transmitter, click
the ’Transmitter’ tab at the bottom
left of the ’System’ window,
and then click the ’Modify’ check-box
to start the programming procedure.
Set the operating frequency channel
of the currently addressed transmitter
by specifying a value between 1 and
250 in the ’Frequency channel’ field.
If a power supply is connected,
the ’State’ field’s status will
be ’Normal’. If the device has no power supply connected, the ’State’ field’s status will be ’Inactive’.
(this feature is only available on devices with firmware version 3.9T or later)
The ’Output power’ field indicates whether the currently addressed transmitter has an adequate
power supply.
The ’Disarmed’ check-box option (only available on devices with firmware version 3.9T or later)
permits the temporary disabling of the transmitter without the need to switch off its power supply.
To activate the settings, click ’Apply’.