SPECIFICATIONS 

 
TRANSMITTER 

 
Power supply  ........................................... +12V nominal, 9V to 35V transient 

 

Operating temperature - Radio ............................................   -40

˚

C to +85

˚

 
Storage temperature........................................................  -40

˚

C to +100

˚

 
Frequency .........................................................................  902-928 MHz 
 
Transmit power (ERIP)................................................................... 10 mW 
 
Vibration ............................................................................ 3G to 200Hz 
 
Shock ...........................................................................................50G 
 

 

There are no user-serviceable parts inside the Transmitter or the 
Receiver.  Return the units to the KAR-TECH for service. 
 
Note:  For operation with negative ground vehicles only. 

 
WARNING:

 

The 

KAR-TECH

 MINI REMOTE must be operated in compliance with all 

applicable safety regulations, rules, and practices.  Failure to follow 
required safety practices may result in death or serious injury. 
 
 

The information, specifications, and illustrations in this manual are those in effect at 
the time of printing. 

KAR-TECH

 reserves the right to change specifications or design at 

any time without notice. 

Summary of Contents for MNTA1 MINI REMOTE

Page 1: ...MNTA1 MINI REMOTETM MINI REMOTE CONTROL SYSTEM PRELIMINARY USER MANUAL March 07 2006...

Page 2: ...I REMOTE i INDEX Description 1 Installation 2 Before applying power 2 Routine Maintenance 3 Maintenance precautions 3 Troubleshooting 3 Troubleshooting chart 4 Specifications 5 Instructions to the Use...

Page 3: ...the RF interference problem in Radio remote products The control system consists of two major modules the remote station this unit and a separate remote receiver Digital Controller sold separately Ea...

Page 4: ...r heavier wire 4 All connections must be properly insulated to protect against shorts FCC REQUIREMENT Any device in which this module is installed must include a label that is clearly visible containi...

Page 5: ...ollowing are general precautions that should be closely followed in carrying out any maintenance work 1 Do not have hydraulic power available to the valves when performing electrical tests or download...

Page 6: ...for proper grounding of vehicle s electrical circuit 7 Check vehicle s hydraulic system 2 Certain functions do not work 1 Check the wiring connection from the receiver to the valve coil or the output...

Page 7: ...ceiver Return the units to the KAR TECH for service Note For operation with negative ground vehicles only WARNING The KAR TECH MINI REMOTE must be operated in compliance with all applicable safety reg...

Page 8: ...radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Th...

Reviews: