![KAPPLER Frontline 500 User Information Download Page 14](http://html1.mh-extra.com/html/kappler/frontline-500/frontline-500_user-information_3436706014.webp)
User Information for Frontline® 500
9
www.kappler.com
PRESSURE TESTING THE GARMENT
The steps in this procedure mirror those found in ASTM F1052 “Standard Test
Method for Pressure Testing Vapor Protective Ensembles”� A copy of the stan-
dard may be obtained for a fee from ASTM International (
www.ASTM.org
)�
The Kappler Pressure Test Kit used for pressure testing will contain either an
airline supply, self-contained blower or both. For training purposes, a video of
the pressure testing procedure is available at www.kappler.com. Additional
literature may be obtained by contacting customer service at 1-800-600-4019
or by email, [email protected].
CONDUCTING THE TEST
1� Unfold the garment and place face down on a smooth, clean surface
where it can be inflated without obstruction�
2� On the inside of the garment, close off all valves and pass-throughs
(if present) that are not needed for pressure testing�
3� Working from the outside of the garment, remove the exhalation valves
caps and diaphragms from the valves� Firmly push the test kit adapters
into the valve openings and turn clockwise to ensure a proper air-tight
seal� If the adapters are not locked into place, a seal will not occur and
the garment will not hold pressure�