1
Pre-Installation Information
To the Installer:
If you are familiar with the installation, you can use the checklist with the
symbol.
Copyright Information
Copyright © 2018 Tyco International Ltd. and its Respective Companies. All rights reserved. All specifications were current as of
publication date and are subject to change without notice. EntraPass, Kantech and the Kantech logo are trademarks of Tyco
International Ltd. and its Respective Companies.
Safety Instructions
ONLY SERVICE PERSONS WILL INSTALL AND MAINTAIN THE KT-315. Service persons must have appropriate technical
training and experience necessary to be aware of the hazards to which they are exposed and of measures to minimize the
danger to themselves or other persons.
The connection to the mains supply must be made as per local authorities rules and regulations: in the UK as per BS6701.
Provide an appropriate disconnect device, as part of the building installation. Where it is not possible to rely on the identification
of the NEUTRAL in the AC MAINS SUPPLY, the disconnecting device must disconnect both poles simultaneously (LINE and
NEUTRAL).
If a knockout is removed during installation, it is the installer’s responsibility to ensure that the same degree of protection is
provided for the cabinet by the use of bushings, fittings, etc.
Secure the metal cabinet to the building structure before operation.
Internal wiring must be routed in a manner that prevents:
•
Excessive strain on wire and on terminal connections;
•
Loosening of terminal connections;
•
Damage of conductor insulation.
The power supply must:
•
Be permanently connected, fail safe, with double or reinforced insulation between primary and secondary circuits.
•
In EU countries it must meet the applicable requirements of the
Low Voltage Directive
.
•
In other countries, it must be of approved type acceptable to local authorities.
The screwdriver supplied within the ACCESSORY KIT for KT-315 must NOT BE USED in ANY ELECTRICAL CIRCUIT that
exceeds the SELV limits: e.g.: 30 V rms or 60V DC under normal operating conditions; DO NOT USE the supplied screwdriver
for ANY MAIN CONNECTIONS to the TERMINAL BLOCK.
The SUPPLIED screwdriver is designated for SERVICE PERSONS ONLY and shall not be left with the OPERATOR of the
system.
The ground connection must be provided via the TERMINAL BLOCK at the PE (IEC 60417-5019 symbol) marked connection.
It is the end-user and/or installer’s responsibility to ensure that the disposal of the used batteries is made according to the waste
recovery and recycling regulations currently applicable.
Components Required to Install KT-315
•
KT-315 Controller with accessory kit
•
AC transformer 120 V/16 VAC, 40 VA, class 2 for the KT-315 N.A. model*
•
One 12 volt battery 7 A/h*
•
Ground clamp*
A visual inspection should be made when unpacking the KT-315. Any missing item/part or damaged component should be
reported immediately.
*Not included