ADJUSTING THE PRESSER FOOT LIFT
■
Foot lift on the machine with spreader 6mm above the
top surface of the needle plate
■
Foot lift on the machine without spreader 7mm above
the top surface of the needle plate
To make the above adjustment, loosen screw D for
crank lever C and then set the clearance between slot
A on the presser bar clamp connection plate and screw
B at 0.5~1mm.
■
Pneumatic presser foot lift
When the cylinder gets actuated, the presser foot
should be 6mm or 7mm above the top surface of the
needle plate. Position stopper E so that lever G
cannot be lowered.
Then secure stopper E with nut F.
■
Electric presser foot lift
When plunger H moves in direction of J, the presser
foot should be 6mm or 7mm above the top surface of
the needle plate. Adjust by using chain I.
Position stopper E so that lever G cannot be lowered.
Then secure stopper E with nut F.