INSTALLATION MANUAL OPERATION MANUAL
KANNAD 406 AP-H
PAGE 106
JUL 24/2013
5. Electrical characteristics
Transmitter power supply: 3 x LiMnO
2
D type cells.
A. Electrical interface
When installed on board, the ELT has to be connected:
• to a Remote Control Panel via a DIN12 connector;
• to an external antenna via a BNC connector.
The DIN12 connector is also used to connect a programming dongle, a CS144
interface or a programming and test equipment.
J1
This connector is dedicated for connection to the Remote Control Panel, to the
Programming or Maintenance Dongles, to a CS144 interface and/or to the
programming equipment (PR600).
IMPORTANT: Shielded cables are recommended. The required wires are
AWG24.
Table 1: J1 connector pin-out
(*)This wire is not used with some versions of Remote Control Panels. For
precise information, refer to Remote Control Panel technical description.
J2
Connector J2 is used to connect the external antenna through a 50
Ω
coaxial
cable for use as fixed ELT or the auxiliary antenna for use as survival ELT.
J1
PIN
Signal Name
Destination Direction
Viewed from
Front Face
J1-A
RCP TEST/RESET RCP
IN
J1-B
DONGLE RX
SMM / PGM IN
J1-C
DONGLE CS
SMM
OUT
J1-D
DONGLE SK
SMM
OUT
J1-E
DONGLE TX
SMM / PGM OUT
J1-F
DONGLE ALE2P
SMM
OUT
J1-G
RCP COMMON
RCP
OUT
J1-H
RCP BUZZER
RCP(*)
OUT
J1-J
RCP LED
RCP
OUT
J1-K
RCP ON
RCP
IN
J1-L
DONGLE GND
SMM / PGM OUT
J1-M
N/C