Page 6 of 25
SafeLink category 2 (Non Float Free)
Remove the beacon from its mounting bracket:
(1) Lift up the red locking pin;
(2) Pull and remove the red locking pin to unlock the bracket;
(3) Extract the beacon from the mounting bracket.
6.2.2. Activation by water switch sensor
Tie the beacon with lanyard before throwing overboard.
The beacon will start to transmit as soon as submerged (water switch sensor activation).
TO STOP BEACON:
remove the beacon from water. Transmission will stop 10 seconds after.
6.2.3. Manual Activation by ON pushbutton
(1) Break the seal by pushing the locking system up.
(2) Press ON pushbutton for 1 at least second.
(3) The buzzer transmits an audible signal every second.
(4) The beacon performs a self-test.
(5) After the self-test, only the white strobe lights blink 3 seconds. The buzzer continues to
transmit every second.
(6) Tie the beacon with the lanyard to the boat or a life raft and throw it overboard.
TO STOP THE BEACON:
press TEST pushbutton.
Summary of Contents for SafeLink EPIRB
Page 1: ...SAFELINK EPIRB User Manual ...
Page 2: ...SafeLink Category 1 ...
Page 3: ...SafeLink Category 2 ...
Page 9: ...Page 4 of 25 ...
Page 25: ...Page 20 of 25 ...
Page 28: ...Page 23 of 25 RELEASE SYSTEM REMPLACEMENT Date Signature Next remplacement ...
Page 31: ......