16 KANE 458s MANUAL
Make sure you do not exceed the analyser’s operating specifications. In
particular:
• Do not exceed the flue probe’s maximum temperature (600°C)
• Do not exceed the analyser’s internal temperature operating range
MEASURING FLUE GASSES
After the countdown is finished and the analyser is correctly set up, put
its flue probe into the appliance’s sampling point. The tip of the probe
should be at the centre of the flue. Use the flue probe’s depth stop cone
to set the position.
With balanced flues, make sure the probe is positioned far enough into
the flue so no air can “back flush” into the probe.
WARNING
Ensure the flue probe handle does not get hot!
MAIN MENU SUB MENU
OPTIONS/COMMENTS
SCREEN
CONTRAST
Factory setting is 14
BACKLIGHT
0 to 300 secs
AUX
Enables users to customise the
parameters on the AUX display: LINE 1,
LINE 2, LINE 3, LINE 4, LINE 5, LINE 6,
BACK
BACK