KANE255 OVERVIEW
The KANE255 Combustion Analyser measures carbon dioxide (CO2),
carbon monoxide (CO) and Flue temperature.
It calculates oxygen (O2), CO/CO2, ratio, losses, combustion efficiency
(Nett, Gross or Condensing) and excess air.
In addition the KANE255 Combustion Analyser’s CO sensor checks CO
levels in ambient air - useful when a CO Alarm is triggered.
The CO reading can be referenced to the oxygen reading in ppm or
mg/m3.
The analyser has a protective rubber cover with integral magnet for
“hands-free” operation and is supplied with a flue probe with integral
temperature sensor.
The large display shows 2 readings at a time and all data can be printed
via an optional infrared printer. The printed data can be 'live' data, 'frozen
data' or stored data. 20 sets of tests can be stored. Two lines of 16
characters can be added to the header of printouts.
The KANE255 combustion analyser is controlled using 4 buttons and a
rotary dial.
The four buttons (from left to right) the power button, switch on and off
the backlight and “freeze” or hold data, switch on and off the pump,
SEND button, to print live readings, if the SEND button is held for 2
seconds the data is stored in the memory, a log number will be briefly
displayed. The buttons with UP, DOWN and ENTER arrows also change
settings such as date, time, fuel source and AUX page settings.
The rotary dial changes the displayed data and selects access to the
menu to make changes to the date, time, etc.