KANE457 manual
Page
26
FAST START METHOD
This allows access to pressure and temperature modes without having to go through
the 90 second Combustion countdown.
With the KANE457 switched off, press and hold down the
/
button and
the
n press and release
/
. Release
/
after MANO_MOD
is displayed on top line.
The KANE457 will now operate as a fixed display thermometer/pressure meter with
the pump off and inhibited. The readings can be printed but not stored.
The display will show:
P
0.00
→
Real time pressure reading.
T1
21.3
→
Use the T1 connection for the flow
temperature sensor.
T2
21.3
→
Use the T2 connection for the return
temperature sensor.
∆T
0.0
→
Real time temperature difference.
PRESSURE ZEROING
In MANO_MOD disconnect any tubing and PRESS and HOLD the PUMP key until the
analyser beeps and the top line shows ZERO CAL.