13
Model
KS 7000E 1/3
KS 10000E 1/3
Voltage, V
230
400
230
400
Max Power, kW
5,5
5,5
8,0
8,0
Nominal Power, kW
5,0
5,0
7,5
7,5
Frequency, Hz
50
50
Current max, A
23,91
9,93
34,78
14,45
Outlets
1*16A (400V),
1*32A (230V)
1*16A (400V)
1*32A (230V)
Fuel Tank Volume, l
25
25
50% power working time
17
15
LED display
voltage, frequency,
working hours
voltage, frequency,
working hours
Noise level
L
PA
/
L
WA
,
dB
72/97
72/97
Power output V/А
12/8,3
12/8,3
Engine model
KS 410
KS 460
Engine type
gasoline 4 stroke cycle
engine
gasoline 4 stroke cycle
engine
Engine power, hp
13
18
Crank case volume, cm
3
1,1
1,2
Engine cylinder volume cm
3
389
440
Power output controller
AVR
AVR
Engine start
manual/electro
manual/electro
Power factor, cosφ
1/0,8
1/0,8
Dimensions (L*W*H), mm
700*545*590
700*545*590
Weight, kg
81,8
95
Protection class
IP23M
IP23M
Altitude (MAX), m
1000
1000
Relative humidity
<95%
<95%
*Acceptable deviation of a current is 5%
To ensure the reliability of the generator and increase its lifespan, the peak capacities
may be slightly limited by circuit breakers.
The optimum operating conditions are ambient temperature of 17 – 25 °C, barometric
pressure of 0.1 MPa (760 mm Hg), and relative humidity of 50 – 60%. Under such
ambient conditions, the generator can guarantee maximum performance in terms
of the stated specifications. In case of deviations from the above ambient values, the
performance of the generator can be different.
Please note that in order to preserve the lifespan of the generator, continuous loads
should not exceed 80% of the rated power.
Summary of Contents for KS 3000