TO STOP THE ENGINE, PROCEED AS FOLLOWS:

1. Disconnect all devices connected to the generator, then disable the ECON mode.

2. Allow the generator to operate at idle for 3 minutes for the alternator to cool down.

3. Set the engine switch to OFF.

4. Turn the fuel valve to the “OFF” position.

Detailed description of operation in AC mode can be found in the full electronic version of the manual.

Detailed description of operation in AC mode can be found in the full electronic version of the manual.

The manufacturer shall not be liable for any damage caused by 

failure to perform maintenance work.

IMPORTANT!

-  If the generator often operates at high temperature or high load, the oil should be replaced 

every 25 operating hours.

- If the engine often runs in dusty or other harsh conditions, clean the air filter every 10 operating hours.
- If you missed the maintenance time, perform it as soon as possible to save the generator engine.

MAINTENANCE

8

This manual compliance! You can find a list of service center addresses on the website of exclusive importer: 

www.ks-power.de/en

.

TECHNICAL MAINTENANCE WORKS

Unit

Action

At each start

First month

 

or 20 operating 

hours

Every 3 months  or 50 operating 

hours

Every 6 months  or 100 operating 

hours

Every year

 

or 300 operating

 

hours

Motor oil

Level check

Replacement

Air filter

Check

Cleaning

Spark plug

Cleaning

Replacement

Fuel tank

Level check

Cleaning

Fuel filter

Replacement

www.ks-power.de/en

   

|

    7

Summary of Contents for KS 1200i

Page 1: ...Please read this manual carefully before use OWNER S MANUAL Inverter Generator KS 1200i EN...

Page 2: ...at a minimum distance of 1 m Keep unauthorized persons children and animals away from work area Wear safety shoes and gloves We care about the environment therefore we consider it expedient to save p...

Page 3: ...pressor or submersible pump IMPORTANT General view of inverter generators description of control panels s General view of inverter generators description of control panels safety symbols and descripti...

Page 4: ...415 Net weight kg 13 Protection class IP23M Nominal voltage tolerance max 5 To ensure reliability and increase the engine service life peak powers may be slightly limited by circuit breakers Theoptim...

Page 5: ...r Improper operation of the cooler can cause damage to the motor inverter or alternator IMPORTANT ENGINE SWITCH ENGINE SWITCH To start the engine turn the engine switch to the ON position To turn off...

Page 6: ...air intake valve on the fuel tank cap Recommended fuel Recommended fuel unleaded gasoline Fuel tank volume Fuel tank volume see specifications table CHECK BEFORE GETTING STARTED 6 If the DC fuse turns...

Page 7: ...load allow the engine to run for 1 2 minutes to warm it up When disconnecting the load after lengthy operation do not turn off the generator Allow the generator to run idle for 1 2 minutes so that it...

Page 8: ...often operates at high temperature or high load the oil should be replaced every 25 operating hours If the engine often runs in dusty or other harsh conditions clean the air filter every 10 operating...

Page 9: ...d excess oil is to be squeezed out SPARK PLUGS TECHNICAL MAINTENANCE 11 DAMPER AND FLAME ARRESTER MAINTENANCE 12 Spark plug has to be intact without soot deposits and to have a correct gap SPARK PLUG...

Page 10: ...methods as well as average device capacities can be found in the full version of the manual of the manual The international manufacturer warranty is 1 year The warranty period starts from the date of...

Page 11: ......

Page 12: ...www ks power de info dimaxgroup de Polska DIMAX International Poland Sp z o o Polen Warczawska 306B 05 082 Stare Babice www ks power pl info pl dimaxgroup de 47 02222 www ks power com ua sales ks pow...

Reviews: